55
6.3.5
Removal and installation of the inlet valve
For removing the inlet valve the steam
cylinder must not be removed
.
1. Detach electric cables (polarity of the cables must not be observed).
2. Release hose clamp and remove the hose from the connector.
3. Unlock union nut of the water pipe and remove water pipe.
4. Loosen the two screws with Phillips screwdriver, then remove inlet valve.
5. Remove strainer insert with pointed pliers
the
installation
of the inlet valve follows the reverse sequence. The union
nut of the water pipe must be tightened by hand only.