12]
LED signal description:
GREEN
glowing
-
the charging slot is ready
GREEN
flashing
-
fully charged &
conservation charge
RED
glowing
-
BATTERY charging
RED
flashing
-
ERROR MESSAGE
(for details, see the error codes chapter)
BLUE
glowing
-
NOTICE - battery cooling off
Automatic charging only continues
after cooling.
The description of the signal encoding is also provided on an included sticker. This
may be attached to the device as required.
Messages/error codes
The BCS 5400/5401 (m) + is equipped with numerous extensive self-monitoring and
analysis functions. The goal is to examine the individual charging requirements of the
battery manufacturer to achieve the max. life cycle of the battery. If a battery or system
function deviates from the specified criteria during the charging cycle, an optical and
acoustic signal message will be provided to the user. The optical signal message takes
place during registration via the attached LED together with an acoustic signal. The
LED flashes again during the signal tone after the process has been completed. If the
battery is removed from the charging adapter, the signal tone repeats and provides
information about the situation. The meaning of the signal tones differs according to
the frequency of the repetitions. The colours of the diodes differ according to:
RED
&
GREEN
Status message (uncritical situation - battery should be evaluated or tested manually. E.g. overloading, over-temperature, etc.
BLUE
Information: The charging process has been interrupted temporarily by the cooling phase, will start after cooling automatically.