The emission of heat from the furnace is adjusted with the registers placed on the front of the thermocooker. These
must be open according to calorific need. The best combustion (minimum emissions) is reached when, loading wood,
most air for combustion passes through the secondary air register.
IMPORTANT
: during normal cooker operation, the register lever, Picture 1 pos.
E
must remain completely inserted
(pushed inwards on the cooker). In this way, excessive fuel consumption is avoided (register closed).
The register regulation necessary in order to obtain nominal calorific output is the following:
Fuel
PRIMARY air
SECONDARY air
WOOD
OPEN
OPEN
The intensity of combustion and therefore the calorific output of your thermocooker are influenced by the chimney.
Good chimney draught requires less regulation of the quantity of combustion air, while insufficient draught requires a
larger quantity.
IMPORTANT
: to check that combustion is taking place correctly, verify that the smoke which comes out of the
chimney is transparent. If it is white, it means that the thermocooker is not regulated correctly or the wood is too
wet; if, on the other hand, the smoke is grey or black, this means that combustion is not complete (a greater
quantity of secondary air is necessary).
11.
OVEN USE
After having cleaned the furnace grill, load the fuel. Thanks to the supply of air for combustion, the oven temperature
can be influenced slightly. Sufficient chimney draught and very clean channels for the flow of scorching flue gas
around the oven are essential for a good cooking result. The flue gas register must be completely drawn towards the
front of the thermocooker.
The oven pan can be placed on various levels. Thick cakes and large roasts should be inserted at the lowest level.
Thin cakes and biscuits go on a medium level. The highest level can be used for heating or browning.
The thermocooker is equipped with a cast iron furnace grill which can be removed using a specific handle. The upper
position optimises the use of the hotplate while the lower one optimises water and oven heating.
12.
ELECTRICAL POWER SUPPLY FAILURE
In the event of an unexpected electrical power supply failure during normal system operation, it will be necessary to
carry out these simple manoeuvres to prevent the water in the boiler starting to boil as a consequence of the lack of
pump operation.
1
Close the primary and secondary air regulators completely in a way to suffocate the flame as much as possible.
2
Open the oven door in order to favour the elimination of the internal heat.
3
Open the flue gas register by pushing the knob placed on the right hand side of the frame; in this way, it will
deviate the residual heat still produced towards the chimney.
13.
OPERATION IN TRANSITION PERIODS
WARNING: For no reason turn on the fire before the system has been completely filled with water; doing so
could cause serious damage to the entire structure
. The system should be kept constantly full of water even
in periods in which the use of the wood burning stove/cooker is not required. During winter any non activity
should involve the addition of anti- freeze.
During transition periods when the external temperatures are higher, if there is a sudden increase of temperature it
can happen that the combustion gases inside the flue cannot be completely sucked up.
The exhaust gases do not come out completely (intense smell of gas). In this case, shake the grating more frequently
and increase the air for the combustion. Then, load a reduced quantity of fuel in order to permit a
rapid burning (growing up of the flames) and the stabilization of the draught.
Then, check that all openings for the cleaning and the connections to the stack are air-tight.
13.1.
NORMAL COOKER USE.
WARNING: For no reason turn on the fire before the system has been completely filled with water; doing so
could cause serious damage to the entire structure
.
If the thermocooker is only to be used for cooking foods, for example during the summer period, it is necessary to
raise the moveable grill to the highest level in order to exclude as much as possible the exchange surface capable of
passing heat to the water; the flue gas register (Picture 1 pos.
D
) must be completely positioned to the
RIGHT
in order
to favour the exhaust of hot flue gases after having heated the cast iron hotplate.