the horizontal stretch must never exceed 2 m (UNI 10683-2005);
•
each bend of the flue gas channel slightly reduces the flue draught which must be compensated if necessary
by elevating it suitably;
•
The UNI 10683-2005 – ITALY regulation requires that under no circumstances must there be more than 2
bends or variations in direction including the intake into the flue.
If the user wishes to use the flue as a fireplace or open hearth, it is necessary to seal the hood below the entrance
point of the flue gas channel pos.
A
Picture 14.
If the flue is then too big (e.g. 30x40cm or 40x50cm), it is necessary to intubate it with a stainless steel tube with a
diameter of at least 200mm, pos.
B
, taking care to close the remaining spaces between the pipe itself and the flue
immediately under the chimney pot pos.
C
.
For any further clarifications, please contact your local dealer!