c)
If the product is installed on a non totally refractory floor, one must foresee a fireproof background.
The floors
made of inflammable material
, such as moquette, parquet or cork etc.,
must be replaced
by a layer of no-
inflammable material, for instance ceramic, stone, glass or steel etc.
(size according to regional law). In case the
replacement of the floor is not possible, the appliance shall be placed on a minimum 12 cm thick slab made of
stone or concrete. The platform must stick out
50 cm’s
on the back and
30 cm’s
sideways
and
50 cm’s
on the
front side over the loading door (Picture 2
B
).
d)
no flammable components (e.g. wall units) must be present above the product.
The chimney stove must operate exclusively with the ash drawer inserted. The solid residue of the combustion
(ashes) must be collected in a hermetic container, resistant to fire. The stove must never be ignited when there are
gas or steam emissions (e.g. glue for linoleum, gasoline, etc.). Never deposit flammable materials near the stove.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace glass, the
handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of these parts without
gloves or the relevant tools.
Warn children of the danger and keep them away during the operation
of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney fire.
4.1. FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door.
b) Close the controls of combustion air.
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
2
dust).
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS.
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable points.
5. FLUE
Essential requirements for a correct operation of the appliance:
•
the internal section must be preferably circular;
•
be thermally insulated and water-proof and produced with materials suitable to resist to heat, combustion
products and possible condensates;
Picture 2
A B
100
30
30
50