3.4.2.
Installation with CHEMINÉE SÉCURITÉ INT components
Step to follow for this type of chimney:
1) Position the fireplace in its location. Temporarily install the ASHT+ elbow on the top of the
fireplace and, using a level, mark with an oval the location where the flue liner will enter the
masonry chimney.
2) In the middle of the oval, drill a hole at 45° in the masonry chimney.
3) Increase the size of the hole until a 45° Tubinox liner elbow can be easily slipped through.
4) Slide the liner down from the top of the masonry chimney until you reach the hole
’s level.
5) Slide a 45° liner elbow through the hole and connect it to the liner.
6) Add a small liner section to the liner elbow, this will allow the liner to extend at least 12"
(measured at the top of the liner) from the masonry chimney.
7) Seal the opening around the liner with high temperature refractory cement.
8) The next steps must be done in the following order:
A. Select the ASHT+ length that will fit between the elbow and the liner so that it will slide at
least 2" over the liner section. (You may need to cut the liner for a better fit).
B. Take that section and the BISUMA or BISPMA cover and slide it over the liner. Make
sure you have enough opening to be able to install the ASHT+ elbow without difficulty.
C. Install the 45° elbow on the fireplace.
D. Slide the length section back down on the elbow and twist lock the two together.
E. Pull the cover down over the length and install the insulation pad over the liner; be
careful to cover the liner completely.
F. Slide back the cover over the insulation and fix it in place using the 3 metal screws
supplied.