AVERTISSEMENT
RISQUE D'EXPLOSION
LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIEL
INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I DIVISION 2/ CLASSE
II DIVISION 2
Pos: 157 /Anleitungen/Motor en/B1091 Dr ehstromm otoren/3. ATEX/!2! Expl osionsgeschützte El ektr omotor en gemäß Class I Div.2_02 @ 72\m od_1619776292502_388.docx @ 2773645 @ @ 1
For these motors, the following information specifically or complimentarily apply.
The motors are suitable for use in Class I Div.2 and may be used at an ambient temperature from -20 °C
to +40 °C.
Type suffix:
ID2
e.g.:
80 LP/4 ID2 CUS TF
Labelling:
Class I Div.2 Group A,
B, C, D with details of
the temperature class
Explosive gas mixtures may cause severe or fatal injuries in combination with hot, electrically live and
moving components of electrical machines.
The increased danger in explosion hazard areas requires especially strict observance of the general
safety and commissioning information. It is necessary that the persons responsible are qualified
according to national and local regulations.
These explosion-protected electrical machines comply with the standards CSA C.22.2 No. 100-14, CSA
C22.2 No. 213-M1987 (R2013), UL Subject 1836, UL 1004-1.
The degree of explosion hazards determines the zone classification. The operator is responsible for the
classification of the zones. The use of motors which are not certified for explosion hazard areas is
prohibited in explosion hazard areas.
Pos: 158 /Anleitungen/Motor en/B1091 Dr ehstromm otoren/3. ATEX/Kabelverschr aubungen_1 [EXN, Class I und II Div.2] @ 7\m od_1431424754843_388.docx @ 218766 @ 3 @ 1
3.7.1 Cable connections
Pos: 159 /Anleitungen/Motor en/B1091 Dr ehstromm otoren/3. ATEX/Kabelverschr aubungen_2 [Class I Div2] @ 72\m od_1620045496645_388.docx @ 2774030 @ @ 1
Cable glands must be certified and suitable for Class I Div 2. explosion hazard areas. Unused openings
must be sealed with approved blind plugs.
For sizes 63 to 132, an isolated cable lug must be provided, if it is used to connect the earthing cable
within the terminal box.
Pos: 160 /Anleitungen/Motor en/B1091 Dr ehstromm otoren/3. ATEX/Klemm enkastendeckel dichtung [EXE, EXN, Z one21+22, Cl ass I und II Div.2] @ 7\mod_1431427943472_388.docx @ 218892 @ 3 @ 1
3.7.2 Terminal box cover seals
The terminal box cover gasket is captively mounted on the terminal box cover. Please only use an
original seal when replacing the seal.
If the terminal box is opened during installation, maintenance, repair, troubleshooting or overhaul, the
terminal box cover must be re-fitted after the work is complete. There must be no dirt on the surface of
the seal or the sealing surface of the terminal box frame.
The screws for the terminal box cover must be tightened with a torque according to the list below.
Tightening torques for terminal box cover screws
Thread diameter
M4
M5
M6
M8
Tightening torque (Nm)
0.8 - 1.2
1.2 - 1.8
1.5 - 2.5
3.0 – 5.0
Pos: 161 /Anleitungen/Motor en/B1091 Dr ehstromm otoren/3. ATEX/Elektrischer Anschl uss [ 22 + Class I und II Div.2] @ 7\m od_1431433133025_388.docx @ 219085 @ 3 @ 1
Содержание 6051302
Страница 1: ...B 1091 en Motors Operating and Assembly Instructions...
Страница 6: ...Motors Operating and Assembly Instructions 6 B 1091 en 2722...
Страница 66: ...Motors Operating and Assembly Instructions 66 B 1091 en 2722 5 Declarations of Conformity...
Страница 67: ...Table of Contents B 1091 en 2722 67...
Страница 68: ...Motors Operating and Assembly Instructions 68 B 1091 en 2722...
Страница 71: ...Table of Contents B 1091 en 2722 71 Ende der Liste f r Textm arke Inhalt...
Страница 72: ...6051302 2722...