24
www.norcold.com
Polar Series N7V, N7X, N7XL / N8V, N8X, N8XL
TROUBLESHOOTING FLOWCHARTS - N7V AND N8V MODELS, cont’d.
Fault Code - Thermistor Fault
Temperature* (°F)
Resistance* (k Ω)
85
8.1 - 9.0
80
9.1 - 10.0
75
10.1 - 11.0
70
11.1 - 12.0
60
12.1 - 13.0
50
15.5 - 16.5
40
22.5 - 23.5
35
24.5 - 25.5
33
28.5 - 29.5
32
30.0 - 32.0
* Approximate values
Possible Cause:
The refrigerator is operating on AC
electric power. The thermistor has been
sensed as inoperable, so temperature
is being controlled via backup operating
system.
Possible Cause:
The refrigerator is operating on propane
gas. The thermistor has been sensed
as inoperable, so temperature is being
controlled via backup operating system.
NOR000711A
Are
wires and
connector
good?
YES
Clean or repair as needed.
NO
Check resistance at thermistor connector
with the thermistor packed in ice.
Check thermistor wire
assembly and connctor
for broken/dirty connections.
Is
thermistor
wire plugged
in?
NO
Plug in thermisor wire.
YES
NORCOLD
Amber, flashes off once every
twenty seconds.
NORCOLD
Green, flashes off once every
twenty seconds.