Polar Series N7V, N7X, N7XL / N8V, N8X, N8XL
Possible Cause:
The DC input voltage to the refrigerator
is too low.
TROUBLESHOOTING FLOWCHARTS - N7V AND N8V MODELS, cont’d.
Fault Code - Flash Pattern 8
Possible Cause:
The DC input voltage to the refrigerator
is too high.
Fault Code - Flash Pattern 9
A flame is sensed at the burner when
there should be none present.
Possible Cause:
The gas valve is “mechanically” stuck
open. Therefore, the main control board
senses a flame is present at the burner
when there should be none
Fault Code - Flash Pattern 5
Replace gas train assembly
The gas valve is
“mechanically” stuck open.
NOR000709A
NORCOLD
Red, flashes on five (5) times,
is off five (5) seconds, repeats.
NORCOLD
Red, flashes on eight (8) times,
is off five (5) seconds, repeats.
NORCOLD
Red, flashes on nine (9) times,
is off five (5) seconds, repeats.
Correct the DC input voltage to the refigerator. Make sure the input
voltage is 12.0 VDC.
Correct the DC input voltage to the refigerator. Make sure the input
voltage is 12.0 VDC.