Refrigerator Service Manual
NX6 / NX8 / NXA Models
Fig. 37 - NORCOLD Fan Kit Wiring Pictorial
Fig. 36 - Fan with Installed NORCOLD Fan Kit
Fan
thermostatic
switch
Fan
+ 12 Vdc connection
- 12 Vdc connection
1 amp
in-line fuse
Red wire
to thermal
switch
Red wire to fan
POWER BOARD
Red Spliced Wire
1AMP
FUSE
Red
Fan
Wire
Red
Wire
THERMOSTAT
12 VDC
GND1
Black Spliced Wire
Black
Wire
Black
Fan
Wire
Red
Wire
FAN
12 Vdc
12 Vdc
Electrical Requirements and Components - cont’d.
COOLING UNIT
Cooling System Monitoring
Hardware Monitoring
All NX and NXA model refrigerators are factory equipped
with a high limit thermal switch mounted to the insulation
canister just above the burner box. Should an abnormally high
temperature occur the thermal switch will OPEN. Anytime the
thermal switch opens, the electronic controls will disable ALL
heat source outputs and the Open High Limit error/fault code
will be displayed on the optical display (Refer to Fault Code
sections).
Reset the thermal switch by pressing the red reset-button
located between the two terminals on the back of the switch.
Refer to Fig. 39 on page 48. When successfully reset, the
resistance between the two terminals will be less than 1 ohm.
NOR000096A
Fig. 39 - Reset Pushbutton
Art02312-1
RH
GND
F3
TS
BK/NR
BR/BR
VDC
VDC
F3
TS
RH
BR/BR
BK/NR
GND
Low Ambient Heater (optional)
Models NXA641.3, NXA6421.3F, NXA841.3, and NXA841.3F
are equipped with a low ambient heater.
Models NX641.3 and NX641.3F MAY be equipped with a low
ambient heater.
This kit supplies DC voltage to the heater any time the
ambient temperature is low enough. Extended storage
during cold weather will drain the vehicle batteries. To
prevent battery drain, remove the 3 Amp fuse from the
low ambient heater. See Fig.38.
Fig. 38 - Wiring Diagram and Pictorial-Low Ambient Heater