![Norcold NX61 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/norcold/nx61/nx61_service-manual_1701148039.webp)
www.norcold.com/cda
39
NX6 / NX8 / NXA Models
Refrigerator Service Manual
Components
When working on the refrigerator LP gas system:
•
Do not alter or modify the burner tube anti-vibration
loop.
•
Do not cross thread
fi
ttings. Exercise extreme care
when connecting and disconnecting propane gas
components.
•
Leak test all of the refrigerator propane gas system
fi
ttings after servicing, replacing, or repairing any LP gas
system component.
Solenoid Gas Valves
The manual shut-off valve and the pressure tap are integrated
into the solenoid gas valve. To manually shut-off gas to the
burner, rotate the knurled shut-off knob one-quarter turn (90
degrees) clockwise until the screw slot on the face of the knob
is vertical or perpendicular to the
fl
ow of gas.
Solenoid Gas Valve Connections
The solenoid gas valve inlet
fi
tting is 3/8 inch, male threads;
the outlet
fi
tting is 1/4 inch, male threads.
Fig. 20 - Solenoid Gas Valve.
LP Gas System - cont’d