Norcold N260 Скачать руководство пользователя страница 7

Service Manual N260 Series - 7

Diagnosing Cooling Problems

WARNING: 

 The refrigerator cooling system is under

pressure.  Do not try to repair or to recharge a defec-
tive cooling system.  The cooling system contains
sodium chromate.  The breathing of certain chromium
compounds can cause cancer.  The cooling system
contents can cause severe skin and eye burns, and
can ignite and burn with an intense flame.  Do not
bend, drop, weld, move, drill, puncture, or hit the
cooling system.

Make sure the cooling unit has the correct ventilation:

-  Make sure that the intake and exhaust vents are not

blocked.

-  Make sure that the air flow through the back of the

refrigerator is not decreased or blocked.

-  Make sure the ventilation baffle is correctly installed.

Examine the cooling unit for leaks.

-  If you smell ammonia, the cooling unit has a leak and

must be replaced.

-  If you see a yellow powder or residue anywhere at the

rear of the refrigerator or in the enclosure, the cooling unit
has a leak and must be replaced.

Determine if  the cooling problem occurs while operating the
refrigerator on LP gas, AC electric, and DC electric:

-  Determine if the selected energy source is operating and

heating correctly:

CAUTION:

  Touch only the outside of the

insulation sleeve.  During normal operation,
some tubes of the cooling unit are hot.  Do not
touch any tubes of the cooling unit.

-  Within 20 minutes of starting the refrigerator, touch

the outside of the insulation sleeve.

-  The outside of the insulation sleeve should be warm

to the touch.

WARNING:

  When cleaning, do not try to remove

the orifice [3] from the orifice adapter [4].  Removal
will damage the orifice and seal of the orifice and can
cause a LP gas leak.  Leaking LP gas can ignite or
explode and result in dangerous personal injury or
death.  Do not clean the orifice with a pin or other
objects.

-  Clean the orifice assembly with air pressure and alcohol

only.

-  Using a wrench, assemble the orifice assembly to the

burner.

-  Assemble the flare nut to the orifice assembly.

-  Examine all of the LP gas connections for leaks.

Wiring Diagram

Wiring Pictorial

The parts or the wiring pictorial are (See Art01022):

1. .......................................................... 120 VAC Power cord
2 .................................................................... Chassis ground
3 ............................................................................ Interrupter
4 .......................................................................... 3 Amp fuse
5 ............................................................................ AC heater
6 ................................................................................. Jumper
7 ..................................................................... Terminal block
8 ............................................. Thermostat / gas safety valve
9 .................................................................... Selector switch
10 ............................................ 20 Amp fuse (3-way models)
11 ............................. 12 VDC Power supply (3-way models)
12 ................................................ DC heater (3-way models)

The parts of the wiring diagram are (See Art01023):

1. ............................................................................. 120 VAC
2 .......................................................................... 3 Amp fuse
3 .......................................................................... Thermostat
4 ............................................................................ AC heater
5 .............................................................................. 120 VAC
6 ............................................................................ AC ground
7 ............................................................................ Spark gap
8 ......................................................................... Piezo lighter
9 .................................................................. Gas safety valve
10 .................................................. Thermocouple interrupter
11 .................................................................... Thermocouple
12 .................................................. +12 VDC (3-way models)
13 ............................................ 20 Amp fuse (3-way models)
14 ................................................ DC heater (3-way models)

-  If the outside of the insulation sleeve is not warm, the

selected energy source may not be operating
correctly.

-  Start up the refrigerator on a different energy source

and repeat the procedure for all energy sources.

-  If the outside of the insulation sleeve is warm to the

touch, make sure the unit is cooling correctly.

-  Within one hour after starting up the refrigerator,

touch the fins on the inside of the fresh food com-
partment.

-  The fins should feel cold to the touch.

-  If the fins do not feel cold to the touch after two

hours, the cooling unit is not operating correctly.

-  If the cooling problem does not occur when operating on

all energy sources, the problem is not the cooling unit.

-  Use the “Troubleshooting Charts” to determine the

cause of the problem.

Содержание N260

Страница 1: ...Part No 619260A 4 98 NORCOLD Inc P O Box 4248 Sidney OH 45365 4248 Service Manual For model N260 a 2 4 cu ft 2 way refrigerator For model N260 3 a 2 4 cu ft 3 way refrigerator ...

Страница 2: ...h property damage WARNING This refrigerator is equipped for the use of LP gas only and can not be changed to use any other fuels natural gas butane etc Incorrect installation adjustment changes to or maintenance of this refrigerator can cause personal injury property damage or both Obey the instructions in this manual to install the intake and exhaust vents Do not install the refrigerator directly...

Страница 3: ...rload can result in an electrical fire if the wires and or fuse sizes are not correct Use only the wire and fuse sizes written in the Owner s Manual and Installation Manual To prevent child entrapment make sure all shelf retainers are correctly fastened and remove the doors before disposng of the refrigerator CAUTION The rear of the refrigerator has sharp edges and corners To prevent cuts or abras...

Страница 4: ... sure there is sufficient intake of fresh air for combustion Make sure the living space is completely isolated from the combustion system of the refrigerator Make sure there is complete and unrestricted ventilation of the flue exhaust which in gas mode can produce carbon monoxide The breathing of carbon monoxide fumes can cause dizziness nausea or in extreme cases death Certified installation need...

Страница 5: ... the battery is connected to the black DC wire on the terminal block of the refrigerator Make sure the DC positive wire from the battery is connected to the red DC wire on the terminal block of the refrigerator Make sure an in line fuse is installed on the DC positive wire as near the battery as possible between the battery and the terminal block of the refrigerator NOTE This in line fuse is neces...

Страница 6: ...ble Turn the selector switch to the DC position Turn the thermostat to the temperature setting that you wish Shut down Turn the selector switch to the OFF position Turn the thermostat to the 1 position Ignition and Start Up Battery drain In AC operation there is no battery drain In DC operation the refrigerator draws 10 12 amps at 12 14 volts If the battery charging stops during DC operation chang...

Страница 7: ...amage the orifice and seal of the orifice and can cause a LP gas leak Leaking LP gas can ignite or explode and result in dangerous personal injury or death Do not clean the orifice with a pin or other objects Clean the orifice assembly with air pressure and alcohol only Using a wrench assemble the orifice assembly to the burner Assemble the flare nut to the orifice assembly Examine all of the LP g...

Страница 8: ...8 Service Manual N260 Series ...

Страница 9: ...Service Manual N260 Series 9 ...

Страница 10: ...10 Service Manual N260 Series ...

Страница 11: ...Examine all the LP gas connections for leaks AC heater 1 Remove the AC power cord from the receptacle 2 Remove the two black wires that connect the AC heater to the terminal block 3 Using a utility knife vertically cut through the insulation that surrounds the flue tube 4 Remove the insulation 5 Pull the AC heater up and out of the heater well 6 Push the replacement AC heater down into the heater ...

Страница 12: ...s for leaks Safety valve 1 Close the valve at the main LP gas tank s 2 Remove the control panel from the back of the refrigerator 3 Remove the thermocouple from the thermocouple inter rupter 4 Remove the wires from the thermocouple interrupter 5 Remove the thermocouple interrupter from the safety valve 6 Remove the LP gas outlet fittng from the safety valve 7 Remove the safety valve from the therm...

Страница 13: ...Service Manual N260 Series 13 ...

Страница 14: ...14 Service Manual N260 Series ...

Отзывы: