Service Manual N260 Series - 3
Specifications
- Do not spray liquids near electrical outlets, connec-
tions, or the refrigerator components. Many liquids
are electrically conductive and can cause a shock
hazard, electrical shorts, and in some cases fire.
- The refrigerator cooling system is under pressure.
Do not try to repair or to recharge a defective cooling
system. The cooling system contains sodium
chromate. The breathing of certain chromium
compounds can cause cancer. The cooling system
contents can cause severe skin and eye burns, and
can ignite and burn with an intense flame. Do not
bend, drop, weld, move, drill, puncture, or hit the
cooling system.
- The storage of flammable materials behind or around
the refrigerator creates a fire hazard. Do not use the
area behind the refrigerator to store flammable
materials (gasoline, cleaning supplies, etc.)
- Do not remove the round ground prong from the
refrigerator AC power cord. Do not use a two prong
adapter or extension cord on the AC power cord.
- A circuit overload can result in an electrical fire if the
wires and/or fuse sizes are not correct. Use only the
wire and fuse sizes written in the “Owner’s Manual
and Installation Manual”
- To prevent child entrapment, make sure all shelf
retainers are correctly fastened and remove the
doors before disposng of the refrigerator.
CAUTION:
- The rear of the refrigerator has sharp edges and
corners. To prevent cuts or abrasions when working
on the refrigerator, be careful and wear cut resistant
gloves.
- Make sure all fasteners and connections are tight.
Operating limits:
AC Operation:
108 VAC Min. - 132 VAC Max.
DC Operation:
11.5 VDC Min. - 15.4 VDC Max.
(3-way models)
LP Gas Operation
10.5 Inch Water Column Min. -
11.5 Inch Water Column Max.
Ratings:
AC Operation:
110 Volts AC, 140 Watts
DC Operation:
12 Volts DC, 140 Watts
(3-way models)
LP Gas Operation:
640 BTU per Hr Input
11 Inch W.C. Gas Supply
No. 10 Orifice (LP10)
Current draws:
AC Heater:
1.3 Amps @ 110 VAC
1.2 Amps @ 120 VAC
Resistance
81.7 - 90.3 Ohms
DC Heater
11.7 Amps @ 12 VDC
10.0 Amps @ 14 VDC
Resistance
.95 - 1.05 Ohms
Replacement fuses (refrigerator control panel):
AC Circuit
3 Amp Type 3AG (1 1/4” x 1/4”)
Norcold P/N: 61654622
DC Circuit:
20 Amp Type 3AG (1 1/4” x 1/4”)
Norcold P/N: 61440522