Norcold N260 Скачать руководство пользователя страница 1

Part No. 619260A (4-98)

NORCOLD, Inc.
P.O. Box 4248
Sidney, OH 45365-4248

Service Manual

For model N260 - a 2.4 cu. ft., 2-way refrigerator.

For model N260.3 - a 2.4 cu. ft., 3-way refrigerator.

Содержание N260

Страница 1: ...Part No 619260A 4 98 NORCOLD Inc P O Box 4248 Sidney OH 45365 4248 Service Manual For model N260 a 2 4 cu ft 2 way refrigerator For model N260 3 a 2 4 cu ft 3 way refrigerator ...

Страница 2: ...h property damage WARNING This refrigerator is equipped for the use of LP gas only and can not be changed to use any other fuels natural gas butane etc Incorrect installation adjustment changes to or maintenance of this refrigerator can cause personal injury property damage or both Obey the instructions in this manual to install the intake and exhaust vents Do not install the refrigerator directly...

Страница 3: ...rload can result in an electrical fire if the wires and or fuse sizes are not correct Use only the wire and fuse sizes written in the Owner s Manual and Installation Manual To prevent child entrapment make sure all shelf retainers are correctly fastened and remove the doors before disposng of the refrigerator CAUTION The rear of the refrigerator has sharp edges and corners To prevent cuts or abras...

Страница 4: ... sure there is sufficient intake of fresh air for combustion Make sure the living space is completely isolated from the combustion system of the refrigerator Make sure there is complete and unrestricted ventilation of the flue exhaust which in gas mode can produce carbon monoxide The breathing of carbon monoxide fumes can cause dizziness nausea or in extreme cases death Certified installation need...

Страница 5: ... the battery is connected to the black DC wire on the terminal block of the refrigerator Make sure the DC positive wire from the battery is connected to the red DC wire on the terminal block of the refrigerator Make sure an in line fuse is installed on the DC positive wire as near the battery as possible between the battery and the terminal block of the refrigerator NOTE This in line fuse is neces...

Страница 6: ...ble Turn the selector switch to the DC position Turn the thermostat to the temperature setting that you wish Shut down Turn the selector switch to the OFF position Turn the thermostat to the 1 position Ignition and Start Up Battery drain In AC operation there is no battery drain In DC operation the refrigerator draws 10 12 amps at 12 14 volts If the battery charging stops during DC operation chang...

Страница 7: ...amage the orifice and seal of the orifice and can cause a LP gas leak Leaking LP gas can ignite or explode and result in dangerous personal injury or death Do not clean the orifice with a pin or other objects Clean the orifice assembly with air pressure and alcohol only Using a wrench assemble the orifice assembly to the burner Assemble the flare nut to the orifice assembly Examine all of the LP g...

Страница 8: ...8 Service Manual N260 Series ...

Страница 9: ...Service Manual N260 Series 9 ...

Страница 10: ...10 Service Manual N260 Series ...

Страница 11: ...Examine all the LP gas connections for leaks AC heater 1 Remove the AC power cord from the receptacle 2 Remove the two black wires that connect the AC heater to the terminal block 3 Using a utility knife vertically cut through the insulation that surrounds the flue tube 4 Remove the insulation 5 Pull the AC heater up and out of the heater well 6 Push the replacement AC heater down into the heater ...

Страница 12: ...s for leaks Safety valve 1 Close the valve at the main LP gas tank s 2 Remove the control panel from the back of the refrigerator 3 Remove the thermocouple from the thermocouple inter rupter 4 Remove the wires from the thermocouple interrupter 5 Remove the thermocouple interrupter from the safety valve 6 Remove the LP gas outlet fittng from the safety valve 7 Remove the safety valve from the therm...

Страница 13: ...Service Manual N260 Series 13 ...

Страница 14: ...14 Service Manual N260 Series ...

Отзывы: