![Norcold 323 Series Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/norcold/323-series/323-series_service-manual_1700882006.webp)
N260.3, 323
6
www.norcold.com
Specifi cations
Rough opening dimensions
(H x W x D)
Model 323 ................................................................................................... 20.63 - 20.76 in. x 17.50 - 17.63 in. x 21.25
Model N260.3 .............................................................................................. 20.81 - 20.87 in. x 19.38 - 19.44 in. x 24.38
DC
power
DC input voltage requirements .....................................................................................................11.5VDC to 15.4VDC
Current
Draw
.......................................................................................................................... 11.7Amps at 12 volts DC
Resistance
.......................................................................................................................................... 0.95 - 1.05 OHM
DC Fuse, F1 on Power Board .........20A, Ø.25 x 1.25L (Littelfuse No. 312020) Automotive Blade, Type APR-20A-Tan
AC
power
AC input voltage requirements ........................................................................................................ 108VAC to 132VAC
AC Fuse - 3A, Ø.25 x 1.25L (Littelfuse No. 312003) .........................................Automotive Blade, Type APR-3A-Violet
Current
Draw
..........................................................................................................................1.3 Amps at 110 volts AC
Resistance
........................................................................................................................................... 81.7 - 90.3 OHM
Propane
gas
Operating pressure (Input pressure to gas valve) ........................................................ 11" W.C Gas 0.5 W.C.
Burner rating (Heat output) ........................................................................................................ 640 BTU/h @ 11” W.C.
Burner
ori
fi
ce size .................................................................................................................................................. LP10
Gas
ignition
.................................................................................................................. Piezo ignitor with
fl
ame sensing
Electrode
tip-to-burner
gap
......................................................................................................................... 1/8" to 3/16"
Off-level operating limits
Side-to-side
....................................................................................................................................3 degrees-maximum
Front-to-back
..................................................................................................................................6 degrees-maximum
Temperature
Sensor
.................................................... Thermostat Capillary Tube, Fin mounted (5th
fi
n from the right)
General Information
To con
fi
rm that installation is adequate, check for:
■
Adequate ventilation - refer to “Ventilation Requirements.”
■
Both gas and electrical components installed and operating in a safe condition.
■
Adequate seal between refrigerator mounting
fl
ange and cut-out opening.
■
Installed on a solid
fl
oor (not on carpet) and secured.
WARNING!
This refrigerator is not intended to be operated as a free standing unit (i.e. where the products of combustion are not completely isolated
from the living area) or installed in such a way as to confl ict with these installation instructions. Unapproved installations could result in safety risks or
performance problems.
!