E-CIRCUIT
–
Installation Guide and User Manual
25
The screen
displays
BT
Buffer battery level too
low; the system
prevents movement
when power levels are
low.
Restore power from the electrical
grid.
The door opens
but does not
close.
The screen
displays
F
Safety options are
obstructed or out of
alignment.
Check the photoelectric barrier’s
alignment with the reflective mirror.
Check that the anti-pinch safety nose
is working properly.
The screen
displays a
countdown
Automatic closure has
been programmed with
a long time delay.
Set the value of the
Tc
parameter to
suit your needs.
The door moves
a few inches and
stops.
The encoder is faulty or
disconnected.
Maintenance request.
The door does
not exit the
learning phase.
The screen
displays
E1
Door width less than
47 in.
[1,200 cm].
Parameters reduction
ratio, pulley diameter,
or encoder resolution
are incorrect.
Check the parameter values:
PE
,
rD
, and
PE
The screen
displays
F
Safety options are
obstructed or out of
alignment.
Check the photoelectric barrier’s
alignment with the reflective mirror.
Check that the anti-pinch safety nose
is working properly.
During the
learning phase,
the door opens
slowly until it
stops, but does
not close.
The screen
displays
E1
The electronics are
faulty.
Maintenance request.
The range of the
remote control is
very low
The radio receiver is
disconnected or
missing.
Replace the radio receiver.
Содержание E-CIRCUIT
Страница 12: ...E CIRCUIT Installation Guide and User Manual 12 Figure 1 Installation Diagram Anti Pinch Safety Edge...
Страница 18: ...E CIRCUIT Installation Guide and User Manual 18 E Circuit Wiring Diagram...
Страница 26: ...E CIRCUIT Installation Guide and User Manual 26 Annex Installation guide CL 1650...
Страница 27: ...E CIRCUIT Installation Guide and User Manual 27...
Страница 28: ...E CIRCUIT Installation Guide and User Manual 28...
Страница 29: ...E CIRCUIT Installation Guide and User Manual 29...