background image

 

│ 

E-CIRCUIT

 

 

Installation Guide and User Manual 

 

21 

 

Partial Opening 

By pressing the Partial button, the door will open partially based on parameter 

LE

, the automatic closure 

parameter is ignored, and the door stays open until another start command is received. 

Flashing Light 

The light under the motor housing provides visual information on the door’s operation. 

-

 

Door is open, the light will flash quickly for the time set in parameter 

TF

, before starting the closing 

movement. 

-

 

Flashes slowly during closing and opening movement. 

-

 

Stays lit during the setup phase. 

-

 

Lights up if power is lost. 

-

 

Lights up if the door is partially open. 

-

 

Lights up if the safety edge detects an obstacle. 

Anti-Pinch Safety Edge (Standard) 

The anti-pinch safety edge installed on the door serves as a mechanical safety edge. When the edge comes 

into contact with an obstacle, the sensor makes the door stop the closing phase and reverse direction. The 

sensor corresponds to NPN-type switch FT1. 

Photoelectric Safety Barrier (Optional) 

The photocell sensor installed on the door and the mirror installed on the frame serve as an invisible barrier. 

When there is an obstacle in the doorway, the sensor makes the door stop the closing phase and reverse 

direction. The sensor corresponds to PNP-type switch FT2. 

Connection Procedure 

Electrical Connections 

 

-

 

Before connecting the power supply, 

make sure that the data on the 

nameplate is compatible with that of 

the distribution network. 

 

-

 

The system power supply must be 

equipped with a circuit breaker in accordance with the regulations in force, located in an easily 

accessible and clearly identified location. 

-

 

The power supply must be equipped with a grounding system that complies with the regulations in 

force. 

-

 

During installation, maintenance, and repair work, disconnect the power supply before opening the 

cover to gain access to electrical parts. 

 

 

Содержание E-CIRCUIT

Страница 1: ...CUIT User Manual and Installation Guide 97 rue de Vaudreuil Boucherville Quebec J4B 1K7 Phone 450 449 1499 Fax 450 641 4657 Toll free 1 877 667 2321 IMPORTANT PLEASE READ PRIOR TO INSTALLATION AND STA...

Страница 2: ...r Optional 14 Installation Procedure Contactless Opening Motion Sensor Optional 16 E Circuit Wiring Diagram 18 User Manual 19 Operating and Configuration Instructions 19 Display 19 Electronic Obstacle...

Страница 3: ...losing of Norbec CL sliding doors The system consists of a transformer and a motor 120 Vac 60 Hz power supply 24 Vdc motor Standard accessories Anti pinch safety edge Pull cord switches 2 Optional acc...

Страница 4: ...ach end as well as the cast iron latch stop 2 Remove the door from the rail to gain access to the top of the door 3 Screw in the motor mounting block on the top of the door 14 in from the edge opposit...

Страница 5: ...tem Components For the installation of the sliding door and frame refer to the CL 1650 sliding door installation guide annexed to this document Installation of the Electrical System Components 1 Insta...

Страница 6: ...UIT Installation Guide and User Manual 6 Opening stop Right opening 2 Attach the end of the belt to the small anchor on the door s closing side 3 Run the belt through the pulley assembly and around th...

Страница 7: ...ach the other end of the belt to the anchor on the door s opening side Mark the length of the belt and cut off the excess To facilitate installation push the door in the opening direction to maintain...

Страница 8: ...E CIRCUIT Installation Guide and User Manual 8 7 Hold the mobile pulley in position 17 mm wrench or adjustable wrench 8 Add the cover to the pulley assembly...

Страница 9: ...ith a cable length of 240 in 600 cm 1 Position the switches in the desired locations 2 Run the cables along to the transformer box 3 Run the cables through the sealed grommet under the transformer 4 C...

Страница 10: ...rding to these dimensions HT 1 500 mm 59 in H1 5 mm 3 16 in H2 710 mm 27 15 16 in H3 1 416 mm 55 3 4 in See p 12 for the complete Installation Diagram Anti Pinch Safety Edge 2 Insert the safety edge o...

Страница 11: ...grommet on the top of the motor 5 Connect the cables according to the following diagram Terminal M5 See p 18 for the complete E Circuit Wiring Diagram 6 Select the switch and commutator near terminal...

Страница 12: ...E CIRCUIT Installation Guide and User Manual 12 Figure 1 Installation Diagram Anti Pinch Safety Edge...

Страница 13: ...ss button P1 on the internal radio receiver once 4 The LED light will turn on 5 Activate the START command on the remote control a Button Press for 2 seconds b Pull switch Pull for 2 seconds 6 When th...

Страница 14: ...o the door underneath the safety nose 2 Run the cabling along the edge and top of the door toward the motor housing Be careful not to expose the top corner of the door opposite the point of contact wi...

Страница 15: ...the cables according to the following diagram Terminal M5 See p 18 for the complete E Circuit Wiring Diagram 6 Select the switch and commutator near terminal M5 of the motor housing Option Switch Comm...

Страница 16: ...r comes with a cable length of 192 in 500 cm 1 Position the switches in the desired locations 2 Run the cables along to the transformer box 3 Run the cables through the sealed grommet under the transf...

Страница 17: ...E CIRCUIT Installation Guide and User Manual 17 5 Follow the procedure for changing parameters and change parameter RA 1 6 Calibrate the operating distance 7 Operates as follows...

Страница 18: ...E CIRCUIT Installation Guide and User Manual 18 E Circuit Wiring Diagram...

Страница 19: ...ered S Stop button pressed E1 First start or power restored after failure press START to start the learning phase E3 Accidental position loss or function change press START to calibrate E4 Double safe...

Страница 20: ...door is closing The door stops and opens again When parameter ST 1 Opening Stop Closure mode After the START command Status Action The door is closed The door opens The door is opening The door stops...

Страница 21: ...h an obstacle the sensor makes the door stop the closing phase and reverse direction The sensor corresponds to NPN type switch FT1 Photoelectric Safety Barrier Optional The photocell sensor installed...

Страница 22: ...disconnected 2 Open the door manually by about 20 in 50 cm 3 Power up the system 4 The screen will display E1 5 Press button P2 Menu to enter setup mode the door s movement is inhibited and the screen...

Страница 23: ...time before automatic closure 4 Flashing time TF 0 10 sec Flashing time before closing movement 2 Assisted opening UE 0 OFF 1 1 Partial opening when manually moving the door Partial opening LE 0 9 0...

Страница 24: ...of Alarms and Problems Problem Display Cause Solution The door does not move The screen is off Loss of power supply Check the status of the electrical grid The screen is off Burned out fuses Replace t...

Страница 25: ...oor moves a few inches and stops The encoder is faulty or disconnected Maintenance request The door does not exit the learning phase The screen displays E1 Door width less than 47 in 1 200 cm Paramete...

Страница 26: ...E CIRCUIT Installation Guide and User Manual 26 Annex Installation guide CL 1650...

Страница 27: ...E CIRCUIT Installation Guide and User Manual 27...

Страница 28: ...E CIRCUIT Installation Guide and User Manual 28...

Страница 29: ...E CIRCUIT Installation Guide and User Manual 29...

Отзывы: