22
Drive Square
To avoid internal damage (especially due to torque overload), the output drive square has been designed to
shear first. This saves major internal damage and allows easy square removal. For drive square part
numbers see page 8.
To replace drive square:
1. Remove the air supply.
2. Support the tool.
3. Remove the screw, then remove drive square.
If the square has sheared it may be necessary to use pliers to remove the broken parts.
4. Fit new drive square.
5. Fit new screw and tighten between 4 N·m to 5 N·m (for PTS-52) or 8 N·m to 9 N·m (for PTS-72/92/80/119).
6. Connect air supply.
TIP: If the drive square fails continually then seek advice from Norbar or a Norbar approved
distributor.
Calibration
To maintain the PneuTorque
®
accuracy it is recommended the tool is recalibrated every 10,000 cycles or
annually, whichever comes first. Contact Norbar or a Norbar distributor for more information.
Cleaning
Keep the tool in a clean condition to aid safety. Do not use abrasives or solvent based cleaners.
Disposal
Recycling Considerations: Please recycle where possible.
The tool has no hazardous disposal requirements.
FIGURE 15
– Square Drive Replacement