12
2. Air Lubrication
The tool must be used with oil lubrication in the supplied air. This is achieved by using a Lubro Control Unit
(not supplied).
Set the air lubrication:
a. Fill Lubro Control Unit with appropriate air-tool grade oil.
b. Ensure the tool drive is free to rotate.
c. Run the tool by pressing the trigger – adjust the tool to max pressure according to the setting data
d. Adjust Lubrication Unit to supply 4 drops of oil per minute.
e. Release trigger
.
See Lubro Control Unit Operator’s Manual for more details.
3. Torque Reaction
The splined reaction ensures large reaction forces are contained within the transmission system, a small
fraction of reaction torque is also passed back to the user; this provides useful operator feedback as torque
levels increase. Several reaction bar styles are available.
Fit reaction bar as detailed below:
Reaction Bar Type
Image
Fitting Instructions
Cranked steel reaction bar (standard)
Fit reaction bar / plate D (Figure
1) over the drive square to
engage reaction splines
Secure with circlip supplied
Cranked aluminium reaction bar
(optional)
Single sided reaction plate (optional)
Double sided reaction plate (optional)
Nose Extension (optional)
Fit as instructions supplied with
nose extension