PAGE 5 OF 13
ISSUE 1
02 2006
SETTING CLOCKWISE/COUNTER-CLOCKWISE OPERATION_________________________
Clockwise
(Arrow towards drive square)
Figure 2a
Counter-clockwise
(Arrow away from drive square)
Figure 2b
TIP: To help set the clockwise / counter-clockwise operation run the tool in
neutral
position before
re-engaging.
Neutral position
Figure 2c
WARNING:
FAILURE TO FULLY ENGAGE THE CLOCKWISE/COUNTER-
CLOCKWISE OPERATION SELECTOR WILL RESULT IN DAMAGE TO
THIS PART OF THE GEARBOX.
SETTING TORQUE FOR BOLT TIGHTENING _______________________________________
The tools use the air pressure set on an external pressure regulator unit to determine the stall torque.
Pneutorques® are supplied with an Air Pressure Graph which relates torque output to air pressure. Set
the torque output as follows:-
1. Ensure the Clockwise/Counter-clockwise Selector (if fitted) is correctly set.
2. Establish the air pressure required using the Air Pressure Graph.
3. With the tool running, adjust the pressure regulator until the correct figure is shown on the gauge.
IMPORTANT:
THE WRENCH MUST BE FREE RUNNING WHILE ADJUSTING THE AIR PRESSURE
TO GIVE THE CORRECT SETTING.
IMPORTANT:
ENSURE THE LUBRO CONTROL UNIT IS SUPPLYING APPROXIMATELY SIX
DROPS OF OIL PER MINUTE WHILE THE TOOL IS FREE RUNNING.
Содержание PNEUTORQUE PTME-72-1000
Страница 2: ......
Страница 14: ...PAGE 12 OF 13 ISSUE 1 02 2006...