Noraxon AMTI Скачать руководство пользователя страница 5

AMTI Force Plate System Setup Guide                                                                                                                                                                                            
 

(Rev B) 

2.2 Analog Integration 

 

 

Step 1-  

Connect the Accupower Force Plate to the PJB-101 Junction box using the RJ11 cables. Connect the power supply. 
 

Step 2- 

Connect the 222K cable to each force plate (if applicable) and connect the single end to the Noraxon AIS. 
  

Step 3-  

Connect the AIS to the PC using the USB A to B cable (CBL02). 
 

Step 4 (optional) 

 

Connect the AIS to the Noraxon MyoSync using 3.5 mm stereo cable. Connect the MyoSync to the PC using the USB A 
to B cable. 

 
 

3  Installing the Companion Software - myoResearch™ 3 

To utilize the full functionality of the AMTI force plate system, ensure the system has updated drivers. 

Noraxon’s 

myoResearch 3

 needs to be installed on the computer.  

 
If integrating digitally with an Optima or Gen5 amplifier, Gen5/Optima drivers are required, which are pre-installed by the 
MR3 software installation. 
 

Software Installation  

Within the package the myoMOTION System was shipped in, there is a 
USB flash drive containing the latest 

myoResearch 3

 software.  

 

1.  Insert the MR3 USB flash drive into the PC 
2.  A menu will automatically pop up 
3.  Click on the Noraxon installation file 

and follow the Wizard’s 

instructions 

 
 

Activating the Software  

The installed companion software must be 

activated 

before unrestricted use is possible. 

 

Содержание AMTI

Страница 1: ...AMTI Force Plate System Setup Guide 1 Rev B AMTI with MyoForce System Setup Guide...

Страница 2: ...and software adjust device settings and record your first data set First you need to determine whether you have the hardware for digital or analog integration Refer to sections 1 and 2 below to deter...

Страница 3: ...3 Rev B 1 2 Analog Integration Figure 1 AMTI force plate Figure 3 Analog Input System Part 222B Figure 3 USB A to B Cable Part CBL2 Figure 4 AIS connection cable Part 222K Junction Box PJB 101 Figure...

Страница 4: ...nd USB port on the PC Step 4 optional Connect the RCA adapter to the Sync cable CBL12 The RCA cable will connect to the Gen5 or Optima amplifier Insert the other end of the Sync cable into any Sync ou...

Страница 5: ...earch 3 To utilize the full functionality of the AMTI force plate system ensure the system has updated drivers Noraxon s myoResearch 3 needs to be installed on the computer If integrating digitally wi...

Страница 6: ...rt will email or respond by phone with the Activation Code Enter the provided Activation Code to remove any restrictions on use 4 Configuring the Hardware 4 1 Digital Integration Before the AMTI syste...

Страница 7: ...log Integration Before the AMTI system can be used the device software settings must be configured to recognize the different components that make up the system Follow the instructions below to recogn...

Страница 8: ...load the acl file that should have come with your AMTI force plates Note If your force plate does not come with an acl file please contact Noraxon Support support noraxon com to discuss other integra...

Страница 9: ...o configure COP tracing relative to body position Measure the gap between your two force plates with a ruler to estimate the most accurate Gap between plates Note For more information on how to config...

Страница 10: ...s and Reporting There are several features available for force plates that require further setup Some examples include Jump Analysis Force Vector Overlay Center of Pressure tracing For more informatio...

Отзывы: