AMTI Force Plate System Setup Guide                                                                                                                                                                                            
 

10 

(Rev B) 

6 Viewing a Record 

To view a previously recorded record, select the 

Database

 tab. Records are organized by 

Project

 and 

Subject

 name. 

Double click on the record of interest to open the record.  
 

7 Analysis and Reporting 

 
There are several features available for force plates that require further setup. Some examples include:  
 

 

Jump Analysis 

 

Force Vector Overlay 

 

Center of Pressure tracing 

 
 
For more information on how to access these features, please see the tutorials available on our website.  

https://www.noraxon.com/video-tutorials/

 

 
 
If you have any other questions not addressed by these resources, please contact 

[email protected]

 for more 

information.

  

Содержание AMTI

Страница 1: ...AMTI Force Plate System Setup Guide 1 Rev B AMTI with MyoForce System Setup Guide...

Страница 2: ...and software adjust device settings and record your first data set First you need to determine whether you have the hardware for digital or analog integration Refer to sections 1 and 2 below to deter...

Страница 3: ...3 Rev B 1 2 Analog Integration Figure 1 AMTI force plate Figure 3 Analog Input System Part 222B Figure 3 USB A to B Cable Part CBL2 Figure 4 AIS connection cable Part 222K Junction Box PJB 101 Figure...

Страница 4: ...nd USB port on the PC Step 4 optional Connect the RCA adapter to the Sync cable CBL12 The RCA cable will connect to the Gen5 or Optima amplifier Insert the other end of the Sync cable into any Sync ou...

Страница 5: ...earch 3 To utilize the full functionality of the AMTI force plate system ensure the system has updated drivers Noraxon s myoResearch 3 needs to be installed on the computer If integrating digitally wi...

Страница 6: ...rt will email or respond by phone with the Activation Code Enter the provided Activation Code to remove any restrictions on use 4 Configuring the Hardware 4 1 Digital Integration Before the AMTI syste...

Страница 7: ...log Integration Before the AMTI system can be used the device software settings must be configured to recognize the different components that make up the system Follow the instructions below to recogn...

Страница 8: ...load the acl file that should have come with your AMTI force plates Note If your force plate does not come with an acl file please contact Noraxon Support support noraxon com to discuss other integra...

Страница 9: ...o configure COP tracing relative to body position Measure the gap between your two force plates with a ruler to estimate the most accurate Gap between plates Note For more information on how to config...

Страница 10: ...s and Reporting There are several features available for force plates that require further setup Some examples include Jump Analysis Force Vector Overlay Center of Pressure tracing For more informatio...

Отзывы: