11
6.3
Ultrasonic Sensor Mounting Guidelines
The following guidelines will ensure optimal sensor performance and prevent sensor
measurement error. These rules should be followed for both the wing sensors and the main
lift (middle) sensor.
1.
In its lowest position, the sensor must be 9 inches (23 cm) or more from the ground
(A)
.
2.
The centerline of the acoustic cone should be approximately vertical at normal operating
heights
(A)
.
3.
The bottom of the sensor must be at least 9 inches in front of the spray nozzles and boom
structure
(B)
. (This does not apply for the main lift sensor)
4.
The bottom of the sensor must be at least 9 inches above the spray nozzles
(C)
.
5.
Ensure there are no other obstructions with a 12 inch (23 cm) diameter circle projected
directly below the sensor
(D)
.
Figure 7: Sensor Mounting Guidelines
Содержание UCB Sx275
Страница 1: ...Versatile Sx275 Installation Manual VS01 ...
Страница 7: ...4 4 Kit Parts 4 1 Kit Overview Figure 2 VS01 System Parts ...
Страница 8: ...5 4 2 Hydraulic Plumbing Figure 3 VS01 Hydraulic Plumbing ...
Страница 31: ...28 12 3 ITEM C03 43220 03 CABLE UC5 NETWORK 14 AWG 3M 12 4 ITEM C05 43210 20 CABLE UC5 NETWORK 18 AWG 20M ...
Страница 32: ...29 12 5 ITEM C10 43230 04 CABLE UC5 VALVE DT TO DT ...
Страница 33: ...30 12 6 ITEM C20 43240 01 CABLE UC5 INTERFACE TILT DT ...
Страница 34: ...31 12 7 ITEM C21 43240 07 CABLE UC5 INTERFACE MAIN DT WITH AUX 1 2 ...
Страница 35: ...32 12 8 ITEM C30 43250 04 CABLE UC5 BATTERY AMP FUSED 5A ...