16
7.2
Roll Sensor Mounting Guidelines: Center Pivot Booms
1.
When mounting the roll sensors, mount one to the boom frame and one to the chassis
(non-pivoting portion of the sprayer). For optimal performance, minimize the distance
between the roll sensors (A) and minimize the height from each roll sensor to the pivot
point (B)
Figure 15: Roll Sensor Mounting on a Center Pivot Suspended Boom
2.
Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.
3.
Both roll sensor cables should be pointing towards the right hand wing of the sprayer.
4.
Ensure both roll sensors are mounted adequately and that the cables provide enough slack
to allow sufficient boom roll.
5.
The chassis roll sensor can also be mounted inverted to minimize the distance between the
roll sensors (
Figure 16
).
Figure 16: Inverted Chassis Roll Sensor Mounting on a Center Pivot Suspended Boom