17
7
Position Sensor Installation
1.
The position sensor (E06) should be mounted such that the largest amount of travel of the
sensor can be utilized without exceeding the travel limit. The sensor install length is 17”
(430mm) center to center with ±3.5” (±90mm) travel recommended. It should be mounted
with the cable on the bottom in a location where the sensor will not bind or contact. Roll
the boom fully in each direction and take measurements to ensure the travel limit is not
exceeded.
Figure 12: Position Sensor Mounting
2.
Mount the position sensor to the brackets using the mounting hardware as shown in
Figure 13
.
Figure 13: Mounting Hardware
Collar
Bolt
Nut
Nut