background image

 

 
 

 

4

3.2

 

Height

 

Sensors

 

 

Height

 

sensors

 

use

 

an

 

ultrasonic

 

signal

 

to

 

measure

 

distance

 

to

 

the

 

ground

 

or

 

crop

 

canopy.

 

 

The

 

number

 

of

 

height

 

sensors

 

will

 

vary

 

from

 

a

 

minimum

 

of

 

two

 

to

 

a

 

maximum

 

of

 

six

 

per

 

system.

  

Three

 

height

 

sensors

 

are

 

normally

 

used.

   

3.3

 

Roll

 

Sensors

 

 

Roll

 

sensors

 

are

 

important

 

for

 

measuring

 

boom

 

and

 

sprayer

 

roll

 

dynamics.

 

 

Two

 

roll

 

sensors

 

are

 

normally

 

used

 

for

 

a

 

UC5™

 

Boom

 

Height

 

Control

 

system.

 

 

The

 

mounting

 

position

 

of

 

the

 

roll

 

sensors

 

vary

 

from

 

sprayer

 

to

 

sprayer

 

depending

 

on

 

boom

 

geometry

 

and

 

suspension.

 

3.4

 

Position

 

Sensors

 

 

Position

 

sensors

 

are

 

used

 

to

 

measure

 

boom

 

suspension

 

position

 

and/or

 

cylinder

 

position.

 

 

The

 

function

 

of

 

position

 

sensors

 

may

 

be

 

similar

 

to

 

that

 

of

 

a

 

pair

 

of

 

roll

 

sensors.

 

 

The

 

mounting

 

position

 

of

 

the

 

position

 

sensors

 

vary

 

from

 

sprayer

 

to

 

sprayer

 

depending

 

on

 

boom

 

geometry

 

and

 

suspension.

 

3.5

 

Modules

 

 

Normally

 

there

 

are

 

three

 

modules

 

included:

 

a

 

control

 

module,

 

an

 

input

 

module,

 

and

 

a

 

valve

 

module.

 

 

Module

 

status

 

is

 

indicated

 

by

 

a

 

LED.

  

Shortly

 

after

 

power

up,

 

the

 

module

 

should

 

present

 

a

 

solid

 

green

 

light,

 

indicating

 

the

 

module

 

is

 

functioning

 

and

 

ready.

 

Содержание UC5 CANbus

Страница 1: ...Quick Guide Virtual Terminal Version 5 Software ...

Страница 2: ...national Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication ...

Страница 3: ... Sensors 4 3 4 Position Sensors 4 3 5 Modules 4 4 Icon Descriptions 5 5 UC5 Operation 7 5 1 Initial Start Up 7 5 2 Main Run Screen 7 5 3 Sprayer Manual Boom Height Switches 8 5 4 Setting Control Options 9 6 Setup 10 6 1 Automatic System Setup 10 6 2 Retune 11 7 UC5 System Maintenance 12 8 UC5 Menu Structure 13 8 1 Setup Sensors 14 8 2 Setup Valves 14 8 3 Setup Switches 14 ...

Страница 4: ...nt Under no circumstances should any service work be performed on the machinery while the UC5 Boom Height Control system is in the automatic mode Always ensure that the UC5 Boom Height Control system is powered down or in manual mode Before leaving the operator s seat While the machine is not moving When transporting the machine Before working on any part of the booms Set the UC5 system to manual ...

Страница 5: ...sidential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This Class A digital apparatus complies with Canadian ICES 003 Pursuant to EMC Directive Article 9 this product is not intended for residential use Table 1 System Specifications Supply Voltage rated 12VDC Supply Current rated 10A Hydraulic Pressure maximum...

Страница 6: ...le 3 Bus Terminator 12 Valve Block 4 2 Way Coupler 13 Input Module 5 3 Way Coupler 14 Left Outer Height Sensor 6 8 Way Coupler 15 Left Inner Height Sensor optional 7 Display 16 Main Lift Height Sensor 8 Control Module 17 Right Inner Height Sensor optional 9 12 VDC Source 18 Right Outer Height Sensor Some UC5 Boom Height Control kits may not include all the components listed above ...

Страница 7: ...sors vary from sprayer to sprayer depending on boom geometry and suspension 3 4 Position Sensors Position sensors are used to measure boom suspension position and or cylinder position The function of position sensors may be similar to that of a pair of roll sensors The mounting position of the position sensors vary from sprayer to sprayer depending on boom geometry and suspension 3 5 Modules Norma...

Страница 8: ...evious Navigates to the previous page Home This button always returns directly to the run screen Manual Mode Active Indicates the system is in manual mode Manual Mode Inactive Changes to manual mode when the system is in automatic mode Automatic Mode Active Indicates the system is in automatic mode Automatic Mode Inactive Changes to automatic mode when the system is in manual mode Settings Navigat...

Страница 9: ...om Geometry Test Starts a boom geometry push test Sensor Setup Diagnostics Navigates to the manual sensor setup or sensor diagnostics screens Valve Setup Diagnostics Navigates to the manual valve setup or hydraulic diagnostics screens Switches Navigates to the manual remote switches screen Versions Navigates to the UC5 modules versions screen Geometry Navigates to the boom geometry screen Manual V...

Страница 10: ...r MANUAL M button When the UC5 system is in manual mode the height displayed under each boom section is measured from the spray nozzles to the soil Soil Mode or crop canopy Crop Mode or Hybrid Mode If there are five height sensors on the sprayer the height displayed is the average for each boom section When the UC5 system is in automatic mode arrows will appear on the screen above or below the boo...

Страница 11: ...to next VT button will appear on the soft key area of the run screen This button allows the user to select the preferred terminal on which to display the UC5 screen By pressing this button the UC5 screen will move to next available terminal 5 3 Sprayer Manual Boom Height Switches When a manual switch is pressed an arrow will be displayed on the screen showing which function is being activated Whil...

Страница 12: ... The height is the target height that the operator would like the boom to be set at when spraying in automatic mode In Hybrid Mode the target height is a combination of measurements to provide a more stable estimate of the distance from the crop canopy to the sprayer nozzles Tips On Off Some sprayers have the ability to fold in the boom tips and spray with only the inner sections of the boom If th...

Страница 13: ...aces Ensure the boom roll suspension system is functioning properly and smoothly Friction on wear surfaces can be relieved using lubricants grease etc or adjustment Properly tuned suspension systems will optimize UC5 performance For best results the hydraulic system should be under a normal load and at a normal working temperature Start the solution pump and run the sprayer s engine at a normal wo...

Страница 14: ...s on the booms Boom Geometry Tuning may not be available for all sprayer types Exit the cab and manually push either boom tip down 30 to 90 cm for a moment and then let go Do not walk near the sensors when approaching the boom Stay at least 1 meter from the sensor to not induce a measurement error Hydraulic Tuning Press and hold the check button to continue with the hydraulic tuning If the button ...

Страница 15: ... below Cleaning Ultrasonic Height Sensors Remove the foam disc from the sensor and wash it with clean water Squeeze out water and allow the foam disc to dry If the transducer inside the sensor is also dirty wash it using clean water Do not submerge or pressure wash the sensor Chemicals or compressed air should never be used The sensor can be used if it is wet however a valid height reading may not...

Страница 16: ...13 8 UC5 Menu Structure ...

Страница 17: ...14 8 1 Setup Sensors The reference frame roll sensor button will only be visible if a reference frame roll sensor is installed in the system 8 2 Setup Valves 8 3 Setup Switches ...