MAIN MENU
Navigating past the end of the menu will return the panel to the operating screen
More ?
More ?
More ?
More ?
Press YES (Auto) to edit or view more sensor settings.
To locate more information on this menu item, refer to Section 5.4.3
Ro
Ro
Ro
Roll 0.5
ll 0.5
ll 0.5
ll 0.5
Displays reading of the main roll sensor.
Depending on sprayer type this menu item may not be displayed.
25 29
25 29
25 29
25 29
Displays readings from optional boom sensors (left inner and
right inner).
This menu item may not be displayed.
31 31 32
31 31 32
31 31 32
31 31 32
Displays the current boom heights, in inches, from left to
right. The heights are adjusted for the offset between the
sensor and nozzles.
If any sensor errors are detected the type of
error will be displayed here
.
30 MM 35
30 MM 35
30 MM 35
30 MM 35
Sensor Display
Menu
↑↑↑↑
SENSOR DISPLAY
/
SETUP
Switch
↓↓↓↓
Setup
Menu
The operating screen is normally displayed.
While at other menu items, if no switch has
been pressed for 30 seconds the panel will
revert to this screen. Also, from any screen, if
you press and hold the Setup switch for two
seconds the panel will return to this screen.
To navigate to the other screens in this table
push the
SENSOR DISPLAY/SETUP
switch
in the indicated direction
Sensi 5
Sensi 5
Sensi 5
Sensi 5
Displays the current control sensitivity setting. A higher
number means a higher sensitivity resulting in more control
actions and quicker response. A lower number will tend
stabilize the boom and make it less active. Range is from 1 to
10.
Soil ON
Soil ON
Soil ON
Soil ON
Or
Crop ON
Crop ON
Crop ON
Crop ON
Use the +/- switch to set the sensor target to Soil or Crop.
ReTune?
ReTune?
ReTune?
ReTune?
Use the Auto (YES) switch to initiate the automatic hydraulic
evaluation of your system. The system will optimize your
system for the best performance possible. The evaluation will
take from one to three minutes.
For a description of the ReTune menu item refer to Section 6.3
More ?
More ?
More ?
More ?
Press YES (Auto) to edit or view more control settings
To locate more information on this menu item, refer to Section 5.4.3 .
Navigating past the end of the menu will return the panel to the operating screen