27
6.5 AUTOMATIC SYSTEM SETUP
* Prepare the Equipment *
WARNING:
•
AT POINTS DURING THE SYSTEM SETUP ALL
BOOM SECTIONS NEED TO MOVE.
•
PERSONNEL AND EQUIPMENT MUST BE CLEAR OF
ALL BOOMS.
•
MAKE SURE ALL BOOMS HAVE ROOM TO LIFT
FULLY AND ARE CLEAR OF POWER LINES.
Step 1
Find a location for the sprayer that is relatively level, and
where the sensors are over bare soil or gravel. Unfold the
booms and (optionally) attach the leveling chains to each
boom section.
Do not conduct the setup or tune procedure over standing
crop, or tall weeds/grass. See Section 6.4 for information on
the use of leveling chains.
Step 2
Unfold the booms, start the solution pump, and run the
sprayer’s engine at a normal working rpm for the entire
test.
Make sure that you can manually adjust the height of all
your booms. If your manual controls do not work normally,
check the installation manual that came with your kit for
troubleshooting information.
For best results, the hydraulic system should be under a
normal load and at a normal working temperature. An
effective way to warm the oil is to cycle all boom sections
up and down manually for 5 minutes. Longer warm up
times may be required in cold weather. For pull type
sprayers, make sure any hydraulic flow controls are adjusted
for normal field operation. Changing the flow controls
during or after system setup will affect UC4 operation.
Step 3
Turn On the UC4 Control Panel.
If this is the first setup for the panel this process will begin
automatically. If the panel was previously setup, you need
to select "Install?" from the setup menu to initiate system
setup.