22
Figure 25 – Cable Configurations: C10 and C11
Read all the following
installation instruction before
connecting the NORAC Power
Cable (C10).
Ensure the UC4 Control Panel’s
power is OFF for the remaining
installation (Bottom of switch
pressed IN). Use caution when
handling the 12 V power line of
the sprayer wiring.
2.
Connect the UC4+ power cable (
C10
)
to the UC4+ Control Panel in the
sprayer cab. Ensure that both plugs
(
P16A
and
P4
) are connected to the
receptacles of the panel (
Figure 25
).
3.
The 3-pin AMP plug (
P3
) on
C10
is
connected to an auxiliary 12 V power
connection in the cab.
4.
Route the receptacle end (
R16
) of
C10
out of the cab.
5.
Connect the 16-pin AMP plug (
P16
) of
the valve extension cable (
C11
) to the
free end (
R16
) of
C10
on the outside
of the cab (
Figure 25
).
6.
Route
C11
to the rear of the sprayer,
in the vicinity of the valve block.
Содержание UC4+ Hardi OEM
Страница 9: ...6 Figure 3 Hydraulic Components Double Acting Figure 4 Hydraulic Components Single Acting ...
Страница 20: ...17 Figure 19 Roll Sensors Mounted on an SPC Eagle Boom Chassis Roll Boom Frame Roll Sensor ...
Страница 30: ...27 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 31: ...28 5 4 ITEM C10 44650 35 POWER GENERIC CABLE PULL TYPE ...
Страница 32: ...29 5 5 ITEM C11 44651 03 VALVE EXTENSION GENERIC CABLE ...
Страница 33: ...30 5 6 ITEM C12 44658 42 INTERFACE CABLE AMP ML ONLY ...
Страница 34: ...31 5 7 ITEM C13 44658 60 BYPASS INTERFACE CABLE AMP ...
Страница 35: ...32 5 8 ITEM C16 44658 49 VALVE CABLE ROLL PIGTAIL ...