15
4.4.2
Chassis Roll Sensor Mounting
1.
It is often best to cable tie the chassis
roll sensor in place. When mounting
the chassis roll sensor follow the
guidelines and refer to
Figure 15
.
The chassis roll sensor must be
mounted on a portion of the
sprayer that does not pivot and
is as close to the boom frame
roll sensor as possible (Figure
13).
a)
Make sure you are using the roll
sensor with the temperature probe
(
E03
).
b)
Ensure the roll sensor is level with
respect to the chassis.
c)
The AMP (circular) connector
MUST exit towards the right
hand wing
.
d)
Make sure the temperature probe is
able to reach the side of the valve
block.
Figure 15 – Chassis Roll Sensor
Mounting
2.
Fasten the temperature probe to the
UC4+ valve block, using the supplied
3/8”x1/2” bolt as shown in
Figure 16
.
3.
Cable-tie the temperature probe cable
and AMP (circular) connector securely
to a frame member.
Check that the roll sensors and
cables will not interfere with, or
come into contact with any
parts of the sprayer.
Figure 16 – Temperature Probe
Attached to the UC4+ Valve Block
Содержание UC4+ Hardi OEM
Страница 9: ...6 Figure 3 Hydraulic Components Double Acting Figure 4 Hydraulic Components Single Acting ...
Страница 20: ...17 Figure 19 Roll Sensors Mounted on an SPC Eagle Boom Chassis Roll Boom Frame Roll Sensor ...
Страница 30: ...27 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 31: ...28 5 4 ITEM C10 44650 35 POWER GENERIC CABLE PULL TYPE ...
Страница 32: ...29 5 5 ITEM C11 44651 03 VALVE EXTENSION GENERIC CABLE ...
Страница 33: ...30 5 6 ITEM C12 44658 42 INTERFACE CABLE AMP ML ONLY ...
Страница 34: ...31 5 7 ITEM C13 44658 60 BYPASS INTERFACE CABLE AMP ...
Страница 35: ...32 5 8 ITEM C16 44658 49 VALVE CABLE ROLL PIGTAIL ...