16
6
Roll Sensor Installation
6.1
Bracket Assembly
1.
Securely mount the roll sensors to the included roll sensor brackets using the #6 machine
screws. Tighten screws to 10 in-lbs (1.1 Nm).
2.
The orientation of the mounted roll sensor to the roll sensor bracket will depend on the
bracket mounting. The roll sensor CANbus connector must be pointing towards the right
side of the sprayer (when looking from the rear of the sprayer).
Figure 11: Mounting Roll Sensor to Bracket
Figure 12: Roll Sensor Orientation - Connector Facing Right Wing