1.5 Type of electrical wires
Depending on the installation, the type and number of devices installed, the number of cables needed can vary. The table
below shows the cables needed for a typical installation. The cables used in the installation must be IEC 60335 compliant.
Power supply line
Cable 3x1,5 mm
2
Motor cable (if not equipped)
Cable 4x1,5 mm
2
Flashing signal
Cable 2x1,5 mm
2
Antenna radio
Shielded cable type RG58
Key selector
Cable 3x0,5 o 0,75 mm
2
Photo Tx
Cable 4x0,5 o 0,75 mm
2
Photo Rx
Cable 3x0,5 o 0,75 mm
2
1.6 Type of installation
1.7 Connections Notes
To guarantee operator safety and to prevent damaging the components, never make connections or insert wireless receiver
boards while the control unit is powered. Power the control unit through a 3 x 1.5 mm
2
cable. If the distance between the
control unit and the ground system connection is more than 30 m, a ground plate must be installed in proximity to the control
unit.
• If the motors do not have a cable, use the 4 x 1.5 mm
2
cable (open + close + ground).
• In connecting the part with an extremely low safety voltage, use cables with a minimum section of 0.5 or 0.75 mm
2
.
• Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit.
• Do not connect the cables in underground cases even if they are water-tight.
• If they are not used, the inputs to the Normally Closed (NC) contacts must be jumpered to the common”
• If the same input has more than one contact (NC), they are placed in series.
• If they are not used, the inputs to the Normally Open (NO) contacts are left loose.
• If the same input has more than one contact (NO), they are to be placed in series.
• The contacts must be mechanical and free of any potential.
Remember that systems for automatic gates and doors must be installed by highly qualifi ed technicians only
and in full compliance with current law.
START-S5PV control unit is designed for roll-up doors or rapid doors.
START-S5PV
Technical manual