background image

The Recovery Speed setting adjusts the speed of target 

response.

It allows for separation between multiple targets in close proximity.
Recovery Speed setting enables you to detect smaller targets 

among trash or ferrous targets.
The LEGEND Recovery Speed setting can be adjusted between 1 

and 10 with 1 being the slowest and 10 being the fastest.

Recovery Speed setting only affects the mode 

currently selected; changes made in one mode do 

not affect the others.

When the Recovery Speed setting is set to a low number, the ability 

of the device to detect targets in close proximity decreases but its 

depth increases.
Similarly, a high Recovery Speed setting (for example 10) will 

increase  the ability of the device to detect targets in close 

proximity but will decrease the depth.
It is recommended that you practice with different metals placed 

close to each other before starting to use this setting.

Adjusting the Recovery Speed

1. Press the Power & Settings Button once. Select the Recovery 

Speed setting using the left and right buttons. The current value 

will be displayed on screen.

2. Change the value of the Recovery Speed using the plus (+) and 

minus (-) buttons.
3. Press the Power & Settings Button once to go back to the main 

screen.

IMPORTANT! 

Increasing the Recovery Speed allows for a 

faster sweep rate with less chance of missing targets. 

Increasing Recovery Speed at the same sweep rate will help 

to eliminate ground noise but it will decrease detection depth.

If you encounter high levels of ground noise on beach sand or 

underwater, try increasing the Recovery Speed .

Default Recovery Speed Settings 

It is used to eliminate the electromagnetic interference that 

the device receives from another detector which operates in 

the same frequency range nearby or from the surroundings 

(high voltage power lines, cellular base stations, wireless 

radios and other electromagnetic devices). 

There are 13 channels available for all frequencies including Multi 

frequency. The central frequency is 7 for all frequencies.

Frequency Shift only affects the mode currently 

selected; changes made in one mode do not affect 

the others.

If too much noise is received when the search coil is lifted in the 

air, this may be caused by the local electromagnetic signals or high 

sensitivity level.
To obtain maximum depth performance, to eliminate the noise 

caused by  electromagnetic interference, try shifting the frequency 

first before decreasing the sensitivity.
Detectors may become noisy due to electrical interference and may 

exhibit erratic behavior such as loss of depth or unstable target ID. 

The Frequency Shift setting allows you to slightly shift the detector 

transmit frequency to eliminate unwanted noise.
Frequency Shift can be done in 2 ways in The LEGEND: Manual 

and Automatic.
In the manual Frequency Shift, the operator listens to each channel 

and selects the one with the least noise.
In the automatic one, the device scans all the channels and picks 

the least noisy one itself. This feature is often referred to as Noise 

Cancellation as well.

Shifting the Frequency

1. Hold the coil stationary and away from the ground.
2. Press the Power & Settings Button once. Select the Frequency 

Shift setting using the left and right buttons. The current channel 

will be displayed on screen.

Manual Use

1. Using the plus (+) and minus (-) buttons, go through the frequency 

channels.
2. Select the one you think is the one with the least interference.

Automatic Use 

1. Press the Pinpoint & Accept/Reject Button once. 
2. The device will start scanning all the channels and each channel 

number will be displayed on screen.
3. When the process is done, automatically selected channel 

number will be displayed and a confirmation sound will be heard.
Press the Power & Settings Button once to go back to the main 

screen.

IMPORTANT! 

Automatic Frequency Shift selects the quietest 

channel based on various criteria. However, sometimes the 

selected channel may still present some noise.

1. Frequency Shift

2. Recovery Speed

Low Recovery Speed

Medium Recovery Speed

High Recovery Speed

PARK

FIELD

BEACH

GOLDFIELD

5
5
5
5

Recovery Speed

Search Mode

15

Park

Goldfield

Beach

Field

Park

Goldfield

Beach

Field

Содержание The LEGEND

Страница 1: ......

Страница 2: ...nly be disassembled and repaired by Nokta Makro Authorized Service Centers Unauthorized disassembly intrusion into the metal detector control housing for any reason voids the warranty IMPORTANT Do not...

Страница 3: ...le on the shaft without stretching too much Then plug the connector to the search coil input socket on the system box and secure by tightening the nut While tightening you may hear clicks indicating t...

Страница 4: ...ou navigate between the discrimination patterns offered by The LEGEND 6 Right and Left Buttons On the main screen they are used to navigate between the modes and in the settings menu they are used to...

Страница 5: ...r 2 Clock and Time Tracking 3 Search Modes 4 Target ID Scale and Notched Out IDs 5 Operating Frequency 6 Sensitivity Indicator 7 Target ID 8 Depth Indicator 9 User Profile Save Delete 10 FerroCheck Ba...

Страница 6: ...unk or glove compartment Do not charge the battery in temperatures over 35 C 95 F or below 0 C 32 F The LEGEND battery can only be replaced by Nokta Makro Detectors or its authorized service centers T...

Страница 7: ...in an upright position your arm is relaxed and the search coil is approximately 5cm 2 above the ground Wrong search coil angle Wrong search coil angle Correct search coil angle It is important to keep...

Страница 8: ...lower the sensitivity setting 5 You can start detecting Certain settings are common to all modes changes in these settings will take effect in all modes Most of the settings are mode based and they on...

Страница 9: ...equency and single frequencies cannot be selected In this mode only the Multi frequency has 2 options Wet sand underwater MW or dry sand with very low salinity WD Each time you press the Frequency But...

Страница 10: ...umerically over the indicator The indicator consists of 5 levels Each level represents 6 units of sensitivity The sensitivity values corresponding to each level on the Depth Indicator are shown below...

Страница 11: ...r the advantage of covering a broader range of targets on all types of terrains Multi frequency compared to single frequencies typically provides more accurate IDs at depth In addition it offers maxim...

Страница 12: ...n the display and ranges between 01 60 The LEGEND s Target ID scale consists of 60 lines each of which represents 1 Target ID In addition to showing the Target ID in the middle of the screen the ID is...

Страница 13: ...t buttons Each time you press the button the Target ID will change on screen Select the ID you want to turn off reject or on accept 2 Press the Pinpoint Accept Reject Button If the ID you selected was...

Страница 14: ...are required to the automatic balance 1 Find a clear spot without metals 2 Push the Ground Balance Button once and release it The ground balance icon will appear in the info section at the top and the...

Страница 15: ...ove the search coil over the target or the target over the search coil in order for the device to detect the target The pinpoint mode is a non motion mode The device continues to give a signal when th...

Страница 16: ...a non ferrous ID However it has both ferrous and non ferrous signal IMPORTANT For the FerroCheck feature to work the detector must receive a strong signal Therefore FerroCheck is designed to work with...

Страница 17: ...equency is 7 for all frequencies Frequency Shift only affects the mode currently selected changes made in one mode do not affect the others If too much noise is received when the search coil is lifted...

Страница 18: ...o section at the top of the screen 4 Tone Settings These advanced tone settings offer various options to modify the sounds The LEGEND generates for targets The tone setting offers 6 sub settings as fo...

Страница 19: ...tone volume and tone frequency for all targets 2 Tone The Target ID scale is divided into 2 zones as ferrous and non ferrous The default point that separates these 2 zones vary based on the selected...

Страница 20: ...shown framed PARK FIELD BEACH GOLDFIELD Search Mode 1 Tone Z 1 10 10 10 10 Z 2 10 10 10 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 1 2 1 1 Z 1 2 1 1 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 5 10 10 10 Z...

Страница 21: ...the left of the ID scale the selected zone will be displayed numerically 4 3 Tone Frequency Target IDs for the selected zone Selected target zone Tone Frequency Level for the selected zone 1 30 Low T...

Страница 22: ...ft Press the plus button once 3 Using the left and right buttons select the Tone Break setting The selected setting will be shown framed 4 Press the plus button to go into the setting 5 The Tone Break...

Страница 23: ...ss the Pinpoint Accept Reject Button once To go back to the main screen press the Power Settings Button once Threshold Tone for Rejected Targets In Park Field and Beach modes The Threshold tone will b...

Страница 24: ...the Power Settings Button once Default Threshold Frequencies 4 6 Threshold Frequency PARK FIELD BEACH GOLDFIELD 5 5 5 13 Threshold Frequency Search Mode 1 30 Low Threshold Frequency High Threshold Fr...

Страница 25: ...gs IMPORTANT Once you save a user profile if you use that profile as the active user profile all changes you make will be saved automatically To keep your saved settings you must choose another user p...

Страница 26: ...ibration icon will be displayed in the info section at the top of the screen 6 Backlight 7 Vibration Park Goldfield Beach Field Park Goldfield Beach Field It enables you to adjust the display backligh...

Страница 27: ...d minus buttons 3 When the wireless connection is turned on the Bluetooth Head phones icon will start blinking in the info section at the top of the screen Once it pairs with any Bluetooth headphones...

Страница 28: ...on screen when this setting is selected When Time Tracking is selected in the settings the user can see how much time he she has spent with The LEGEND in year month day hour format Displaying the Usa...

Страница 29: ...djustable Threshold Yes Notch Filter Yes Ground Balance Automatic Manual Tracking Pinpoint Yes Frequency Shift Yes Noise Cancellation Yes Vibration Yes Sensitivity Setting 30 levels Target ID 01 60 Se...

Страница 30: ......

Отзывы: