Sensitivity is the depth setting of the device. It is also
used to eliminate the ambient electromagnetic signals
from the surrounding environment and noise signals
transmitted from ground.
Sensitivity consists of 30 levels and default setting is 25.
Sensitivity setting is a personal preference. However, It
is important to set the sensitivity to the highest level
possible where no major popping sounds are heard to
avoid missing smaller and deeper targets. For example; if
the noise level is suitable for searching and is the same
at level 25 and 30, then 30 should be preferred.
Sensitivity is a common setting for all modes and
changes to this setting will affect them all.
Adjusting the Sensitivity
On the main screen, use the plus (+) and minus (-) buttons to
increase or decrease the sensitivity. Single click to change the
values one by one or hold down to change them rapidly.
The Sensitivity Indicator is located on the left side of the Target ID.
The exact sensitivity level is shown numerically over the indicator.
The indicator consists of 5 levels. Each level represents 6 units of
sensitivity.
The sensitivity values corresponding to each level on the Depth
Indicator are shown below:
The device always starts with the last adjusted sensitivity level.
IMPORTANT!
To obtain maximum depth performance, to
eliminate the noise caused by electromagnetic interference,
try shifting the frequency first.
25-30
19-24
13-18
7-12
1-6
SENSITIVITY
TARGET DEPTH
The device provides an estimated target depth according
to the signal strength during detection.
Depth Indicator:
It shows the target's proximity to the
surface in 5 levels during detection. As the target gets
closer, the levels decrease and vice versa.
Depth detection is adjusted presuming that the target is a 2.5cm
(1'') coin. Actual depth varies according to the size of the target. For
instance, the detector will indicate more depth for a target smaller
than a 2.5cm (1'') coin and less depth for a larger target.
IMPORTANT!
As the operating frequency of the device has a
direct impact on device, the estimated depth may vary for the
same target during frequency changes.
Shallow target
Deep target
8
Park
Goldfield
Beach
Field