background image

Sensitivity is the depth setting of the device. It is also 

used to eliminate the ambient electromagnetic signals 

from the surrounding environment and noise signals 

transmitted from ground.
Sensitivity consists of 30 levels and default setting is 25.
Sensitivity setting is a personal preference. However, It 

is important to set the sensitivity to the highest level 

possible where no major popping sounds are heard to 

avoid missing smaller and deeper targets. For example; if 

the noise level is suitable for searching and is the same 

at level 25 and 30, then 30 should be preferred.

Sensitivity is a common setting for all modes and 

changes to this setting will affect them all.

Adjusting the Sensitivity

On the main screen,  use the plus (+) and minus (-) buttons to 

increase or decrease the sensitivity. Single click to change the 

values one by one or hold down to change them rapidly.
The Sensitivity Indicator is located on the left side of the Target ID. 

The exact sensitivity level is shown numerically over the indicator. 

The indicator consists of 5 levels. Each level represents 6 units  of 

sensitivity. 
The sensitivity values corresponding to each level on the Depth 

Indicator are shown below:

The device always starts with the last adjusted sensitivity level.

IMPORTANT!

 To obtain maximum depth performance, to 

eliminate the noise caused by  electromagnetic interference, 

try shifting the frequency first.

25-30

19-24

13-18

7-12

1-6

SENSITIVITY

TARGET DEPTH

The device provides an estimated target depth according 

to the signal strength during detection. 

Depth Indicator: 

It shows the target's proximity to the 

surface in 5 levels during detection. As the target gets 

closer, the levels decrease and vice versa.

Depth detection is adjusted presuming that the target is a 2.5cm 

(1'') coin. Actual depth varies according to the size of the target. For 

instance, the detector will indicate more depth for a target smaller 

than a 2.5cm (1'') coin and less depth for a larger target.

IMPORTANT!

 As the operating frequency of the device has a 

direct impact on device, the estimated depth may vary for the 

same target during frequency changes.

Shallow target

Deep target

8

Park

Goldfield

Beach

Field

Содержание The LEGEND

Страница 1: ......

Страница 2: ...nly be disassembled and repaired by Nokta Makro Authorized Service Centers Unauthorized disassembly intrusion into the metal detector control housing for any reason voids the warranty IMPORTANT Do not...

Страница 3: ...le on the shaft without stretching too much Then plug the connector to the search coil input socket on the system box and secure by tightening the nut While tightening you may hear clicks indicating t...

Страница 4: ...ou navigate between the discrimination patterns offered by The LEGEND 6 Right and Left Buttons On the main screen they are used to navigate between the modes and in the settings menu they are used to...

Страница 5: ...r 2 Clock and Time Tracking 3 Search Modes 4 Target ID Scale and Notched Out IDs 5 Operating Frequency 6 Sensitivity Indicator 7 Target ID 8 Depth Indicator 9 User Profile Save Delete 10 FerroCheck Ba...

Страница 6: ...unk or glove compartment Do not charge the battery in temperatures over 35 C 95 F or below 0 C 32 F The LEGEND battery can only be replaced by Nokta Makro Detectors or its authorized service centers T...

Страница 7: ...in an upright position your arm is relaxed and the search coil is approximately 5cm 2 above the ground Wrong search coil angle Wrong search coil angle Correct search coil angle It is important to keep...

Страница 8: ...lower the sensitivity setting 5 You can start detecting Certain settings are common to all modes changes in these settings will take effect in all modes Most of the settings are mode based and they on...

Страница 9: ...equency and single frequencies cannot be selected In this mode only the Multi frequency has 2 options Wet sand underwater MW or dry sand with very low salinity WD Each time you press the Frequency But...

Страница 10: ...umerically over the indicator The indicator consists of 5 levels Each level represents 6 units of sensitivity The sensitivity values corresponding to each level on the Depth Indicator are shown below...

Страница 11: ...r the advantage of covering a broader range of targets on all types of terrains Multi frequency compared to single frequencies typically provides more accurate IDs at depth In addition it offers maxim...

Страница 12: ...n the display and ranges between 01 60 The LEGEND s Target ID scale consists of 60 lines each of which represents 1 Target ID In addition to showing the Target ID in the middle of the screen the ID is...

Страница 13: ...t buttons Each time you press the button the Target ID will change on screen Select the ID you want to turn off reject or on accept 2 Press the Pinpoint Accept Reject Button If the ID you selected was...

Страница 14: ...are required to the automatic balance 1 Find a clear spot without metals 2 Push the Ground Balance Button once and release it The ground balance icon will appear in the info section at the top and the...

Страница 15: ...ove the search coil over the target or the target over the search coil in order for the device to detect the target The pinpoint mode is a non motion mode The device continues to give a signal when th...

Страница 16: ...a non ferrous ID However it has both ferrous and non ferrous signal IMPORTANT For the FerroCheck feature to work the detector must receive a strong signal Therefore FerroCheck is designed to work with...

Страница 17: ...equency is 7 for all frequencies Frequency Shift only affects the mode currently selected changes made in one mode do not affect the others If too much noise is received when the search coil is lifted...

Страница 18: ...o section at the top of the screen 4 Tone Settings These advanced tone settings offer various options to modify the sounds The LEGEND generates for targets The tone setting offers 6 sub settings as fo...

Страница 19: ...tone volume and tone frequency for all targets 2 Tone The Target ID scale is divided into 2 zones as ferrous and non ferrous The default point that separates these 2 zones vary based on the selected...

Страница 20: ...shown framed PARK FIELD BEACH GOLDFIELD Search Mode 1 Tone Z 1 10 10 10 10 Z 2 10 10 10 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 1 2 1 1 Z 1 2 1 1 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 5 10 10 10 Z...

Страница 21: ...the left of the ID scale the selected zone will be displayed numerically 4 3 Tone Frequency Target IDs for the selected zone Selected target zone Tone Frequency Level for the selected zone 1 30 Low T...

Страница 22: ...ft Press the plus button once 3 Using the left and right buttons select the Tone Break setting The selected setting will be shown framed 4 Press the plus button to go into the setting 5 The Tone Break...

Страница 23: ...ss the Pinpoint Accept Reject Button once To go back to the main screen press the Power Settings Button once Threshold Tone for Rejected Targets In Park Field and Beach modes The Threshold tone will b...

Страница 24: ...the Power Settings Button once Default Threshold Frequencies 4 6 Threshold Frequency PARK FIELD BEACH GOLDFIELD 5 5 5 13 Threshold Frequency Search Mode 1 30 Low Threshold Frequency High Threshold Fr...

Страница 25: ...gs IMPORTANT Once you save a user profile if you use that profile as the active user profile all changes you make will be saved automatically To keep your saved settings you must choose another user p...

Страница 26: ...ibration icon will be displayed in the info section at the top of the screen 6 Backlight 7 Vibration Park Goldfield Beach Field Park Goldfield Beach Field It enables you to adjust the display backligh...

Страница 27: ...d minus buttons 3 When the wireless connection is turned on the Bluetooth Head phones icon will start blinking in the info section at the top of the screen Once it pairs with any Bluetooth headphones...

Страница 28: ...on screen when this setting is selected When Time Tracking is selected in the settings the user can see how much time he she has spent with The LEGEND in year month day hour format Displaying the Usa...

Страница 29: ...djustable Threshold Yes Notch Filter Yes Ground Balance Automatic Manual Tracking Pinpoint Yes Frequency Shift Yes Noise Cancellation Yes Vibration Yes Sensitivity Setting 30 levels Target ID 01 60 Se...

Страница 30: ......

Отзывы: