Description
Parameter
Min
Typ
Max
Unit
Notes
Differential
voltage
swing
VOD
100
150
200
mV
-2
Operating
frequency
fCLK
1
200
MHz
SW controls
frequency
Differential
rise and fall
time
300
800
ps
-3
Note:
• Common mode voltage is a mean value of high and low states of one single-ended signal.
• Differential voltage swing is differential amplitude between signals of differential pair.
• Differential transitions should be only measured with good equipment (bandwith > 1GHz),
otherwise results will seem too slow.
Table 27 Unagi Camera supply voltage characteristics
Description
Parameter
Min
Typ
Max
Unit
Camera analog
voltage
VDD
2.6
2.8
2.9
V
Camera digital
voltage
VDDI
1.4
1.5
1.6V
V
Table 28 Unagi Camera control IF electrical characteristics
Description
Parameter
Min
Typ
Max
Unit
Notes
ExtClk
VIH square
wave
0.8 x VDD
-
VDD
V
High-level
input
voltage
ExtClk
VIL square
wave
0
-
0.54
V
Low-level
input
voltage
ExtClk
p-p
sinusoidal
wave
0.5
-
1.2
V
Sinusoidal
mode
voltage
swing
ExtClk
Frequency
9.6
MHz
SW
controlled
frequency
SDA, SCL
VIH
0.7 x VDD
1.8
VDD
V
High-level
input
voltage
SDA, SCL
VIL
0
-
0.54
V
Low-level
input
voltage