APE Clocking
APE clocks
trouble
shooting
Clk32k (J4815):
Voh ~ 2.8V &
f ~ 32.768kHz ?
(Figure 1)
Check completed
Reflash the phone
first and check that
Clk32k is not shorted
to GND or some
power line. If Clk32k
still doesn't w ork,
change UEM
Check solder joints
of V6031 and
replace the
component, if
necessary.
Change B4800. If
this doesn't help,
change C4800,
C4801 and C4802.
Fix solder joints
12Mhz clock
(C4800, OSC1_IN):
Vpp ~ 1.7V &
f ~ 12.0MHz ?
(Figure 3)
Yes
Yes
SleepClk ( J2802):
Voh ~ 1.8V &
f ~ 32.768kHz ?
(Figure 2)
No
No
Go to CMT clocks
troubleshooting
Yes
Solder joints of
C4800, C4801,
C4802 and B4800
OK ?
Measure
resistance over
C4801.
R >>1M ?
No
Yes
Yes
No
Solder joints of
OMAP1510
damaged
Check that
(C4800, OSC1_IN)
DC-offset ~ 720mV
(C4802, OSC1_OUT)
DC-offset ~760mV
(Figures 3&4)
No
No
Yes