RH-59/60
Nokia Customer Care
28
COMPANY CONFIDENTIAL
ISSUE 1 09/2004
Copyright © 2004 Nokia. All Rights Reserved.
By measuring with an oscilloscope at RXIP or RXQP on a working GSM 1900 receiver this pic-
ture should be seen.
Signal amplitude peak-peak 460 mV
DC offset 1.2 V
Figure 21: RX1900 I/Q signal waveform