ISSUE 1 09/2004
COMPANY CONFIDENTIAL
39
Copyright © 2004 Nokia. All Rights Reserved.
RH-59/60
Nokia Customer Care
By measuring with an oscilloscope at RXIP or RXQP on a working GSM 900 receiver this pic-
ture should be seen.
Signal amplitude peak-peak 789 mV
DC offset 1.2 V
Figure 33:RX900 I/Q signal waveform