CCS Technical Documentation
Troubleshooting - RF
RH-3
Issue 1 06/2003
Nokia Corporation Confidential
Page 9
* Depends on VBATT
Cell PMIC
The following table illustrates the PMIC troubleshooting information.
PA Power and Gain Measurements
Power Amplifier Input
Test Point
Power Amplifier Output
Test Point
pin3-Z601
right-R814
PA Power and Gain Specifications
Mode
Name
Power
Output
Range
Nominal
Gain
Vcc Range
Vcc Test
Point
Gain mode 0
V0
up to 9
23.8
0.75- 0.88
C806
Gain mode 1
V1
9 to 13
25.2
1.125- 1.375
C806
Gain mode 3
V2
Not used
Not used
2 - 2.5
C806
Gain mode 2
Bypass
13 up
29
3 - 4
C806
Overall Gain
V0 to
Bypass
9
3.5 to 7.3
+/- 0.5
unit
N/A
dBm
dB
VDC
N/A
PA Gain Step
Gen IO 12 GenIO13
PA Vcc
volt (v)
Spec
Name
L
L
0.8
V0
H
L
1.2
V1
L
H
2.2
V2
H
H
3.7
Bypass
Setup:
Mode
Tx
Rx
Band
Local
On
On
PCS/CELL