CCS Technical Documentation
Troubleshooting - RF
RH-3
Issue 1 06/2003
Nokia Corporation Confidential
Page 7
5 Ensure MIN, MDN, and SID are entered into the phone.
6 Ensure VCTCXO is centered, as described in VCTCXO tuning description.
7 Ensure transmitter and receiver are working properly by checking them in local
mode.
Transmitter Troubleshooting
Cell Transmitter
Cell Transmitter Path
The following table indicates the test points to probe when troubleshooting the cell
transmitter path. The steps shown are the recommended but do not have to be followed
in that order. Refer to the Appendix for a reference diagram that illustrates the test
points on the circuit board. An HP high frequency probe is used to make the frequency
and output power measurements.
Constant Reference
Values
CELL Oscillator and IF:
VHF Tx Lo
457.2
Tx IF
228.6
VHF Rx Lo
367.2
Rx IF
183.6
Setup:
Mode
Tx
Rx
Band
CW or
CDMA
BB GenIO
PDM
Rho
Local
On
On
PCS/CELL
CDMA
GenIO 8 = H
TxIF and RF
AGC = 0
On
Chnn
Tx Freq
Rx Freq
UHF
GenIO 12 = L
384
836.52
881.52
1065.12
GenIO 13 = L
600
1880
1960
2143.6