NHM-2/5nx,ny/6/9
Troubleshooting
PAMS Technical Documentation
3DJH
1RNLD&RUSRUDWLRQ
,VVXH$SULO
)DXOWILQGLQJFKDUWIRU*60UHFHLYHU
GSM1800 RX
Troubleshooting
Apply -55dBm
1842.867MHz signal from
generator to antenna
connector
Oscilloscope at RXI and RXQ
Signal 570mVpp
DC offset 1,2V
Frequency 67kHz
Spectrumanalyzer
PCN LNA out
-58dBm
Spectrumanalyzer
1st Dual SAW
GSM1800 out
-83dBm
Oscilloscope
LNA_P 2.4-2.8V
LNAB_G 2.4-2.8V
Spectrumanalyzer
T500 unbal
-60dBm
Oscilloscope
VRX 2.7V
Hagar serial
interface OK
PCN_RX_SW
-81dBm
Spectrumanalyzer
No
No
No
Check
C519, Z500
Yes
Check
T500, C507,
C515, L500
Hagar N500,
Yes
Check BB
No
Yes
No
Yes
No
Yes
Oscilloscope
VRX 2.7V
Hagar serial
interface OK
Check BB
Oscilloscope
V500, RFout 2.6-2.7V
V500, RFin 0.8-0.9V
Yes
No
Check
V500, C517, C519
Check V500,
R513, L502, C519
C517,C509,C510,
R506, C521, C511
Yes
Check Hagar
N500
Check 1st Dual
RX SAW Z501,
C547
Check RX/TX
Switch
Z502
No
Yes
GSM1800 chain
functional
Local Continuos mode
Set to Local Mode
PCN RX continuos
Channel = 700
AGC abs. = 4
Check Hagar N500,
T500, C507, C515, L500
C512, C514, R504
Both
NOT ok
Both signals ok
One signal ok
Spectrumanalyzer
C593/L510
-76dBm
No
Check
Signal Generator,
Antenna adapter
Yes
Go to
Troubleshooting chart
RX Normal Mode
Go to
Troubleshooting chart
PLL Synthezizer