NHM-2/5nx,ny/6/9
Troubleshooting
PAMS Technical Documentation
3DJH
1RNLD&RUSRUDWLRQ
,VVXH$SULO
)DXOWILQGLQJFKDUWIRU(*60UHFHLYHU
EGSM RX
Troubleshooting
Apply -55dBm
942.667MHz signal from
generator to antenna
connector
Oscilloscope at RXI and RXQ
Signal 550mVpp
DC offset 1,2V
Frequency 67kHz
Spectrumanalyzer
GSM LNA out
-58dBm
Spectrumanalyzer
1st Dual SAW
GSM900 out
-77dBm
Oscilloscope
LNA_G 2.4-2.8V
LNAB_D 2.4-2.8V
Spectrumanalyzer
T501 unbal
-59dBm
Oscilloscope
VRX 2.7V
Hagar serial
interface OK
GSM_RX_SW
-76dBm
Spectrumanalyzer
No
No
No
Check
C534, Z500
Yes
Check
T501, C520,
C528, L504
Hagar N500,
Yes
Check BB
No
Yes
No
Yes
No
Yes
Oscilloscope
VRX 2.7V
Hagar serial
interface OK
Check BB
Yes
No
Check V501,
C537, L520, C534
C541, L507, C545
Check V501,
R508, C530, R530
C533, C541, C537
L506, R514, C539
Yes
Check Hagar
N500
Check 1st Dual
RX SAW Z501,
C556
Check RX/TX
Switch
Z502
No
Yes
EGSM chain functional
Local Continuos mode
Set to Local Mode
EGSM RX continuos
Channel = 38
AGC abs. = 4
Check Hagar N500,
T501, C520, C528, L504
C512, C514, R504
Both
NOT ok
Both signals ok
One signal ok
Spectrumanalyzer
C593/L510
-74dBm
Yes
No
Check
Signal Generator,
Antenna adapter
Go to
Troubleshooting chart
GSM1800 RX
Go to
Troubleshooting chart
PLL Synthezizer
Oscilloscope
V501, RFout 2.1-2.2V
V501, RFin 0.8-0.9V