![Nokia DNT2Mi mp Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/nokia/dnt2mi-mp/dnt2mi-mp_operating-instructions-manual_255307074.webp)
Data Network Terminal Single-port and Multiport Operating Instructions
74 (128)
© Nokia Corporation
DN01145897
Nokia Proprietary and Confidential
Issue 2-0 en
8.4.2
Monitoring a line
Figure 51.
Front panel menus for monitoring a line
RX ES: xxxx
Noise margin [dB]
L1: xx L2: xx
Attenuation [dB]
L1: xx L2: xx
Rx level [dBm]
L1: xx L2: xx
OK
EX
Monitor line
Measurements
Monitor
Line
Tx level [dBm]
L1: xx L2: xx
OK
EX
Monitor line
Statistics
Signal qual. L1
15 min periods
Start time 0
d:xx h:xx m:xx
RX UAT: xxxx
OK
EX
Line voltage V
xxx
OK
EX
Start time 1
d:xx h:xx m:xx
RX SES: xxxx
RX BBE: xxxx
Signal qual. L1
24 h periods
Signal qual. L2
24h periods
Signal qual. L2
15 min periods
Start time 3
d:xx h:xx m:xx