TFE-4/RV-1
Company Confidential
General Information
Nokia Customer Care
Page 1-8
Copyright
©
2005
Nokia Corporation.
Issue 2.0 Mar/2005
Company Confidential
Environmental Conditions
The transceiver is not protected against ingress of water. The transceiver may be instantaneously sub-
jected to splashed or condensed water. Longer-term contact with water will cause permanent damage.
Vibration
Temperature
Car connector
X104 Molex 43045-0421
Micro-Fit 3.0 2x2
Speaker connector
X105 SMK LGY2501-0500E
3.5 mm jack
Microphone connector
X106 SMK LGK2509-0600E
2.5 mm jack
Input device, Handset
and Headset connector
X107 Stewart SS-641010-NF-K2
Modular connector RJ-45 K2
Table 7: Temperature ranges
Parameter
Requirement
Test Reference
Duration
Acceptance
Criteria
Vibration
(random)
Operational
10Hz-7m
2
/s
3
50Hz-3,5m
2
/s
3
60Hz-1,75m
2
/s
3
1000Hz-0,06m
2
/s
3
combined with gradual
change of temperature
1 cycle during 8h
DIN 72300-3 (draft)
Env.Hdbk. 4A: Climatic
and Mechanics
IEC 68-2-64
8h/axis
Normal
Performance
or Reduced
performance
Bump
Operational
halfsine
6ms
25g
IEC68-2-29 Eb
Env.Hdbk. 4A: Climatic
and Mechanics
1000 shocks
per 6 directions
Normal
Performance
Shock Non-
operational
halfsine
6ms
100g
IEC68-2-27
3 shocks per
6 directions
Normal
Performance
Table 8: Temperature ranges
Condition
Temperature range
Notes
Normal Operation
-10
°
C to +55
°
C
Specifications fulfilled
Reduced Operation
-20
°
C to +70
°
C
Operational only for short periods.
Intermittent Operation
-30
°
C to +80
°
C
Operation not guaranteed but an attempt to operate
will not damage the phone.
Storage
-30
°
C to +80
°
C
Non operational, 72 h
Table 6: List of external connectors
Connector Name
Conn.
Manufacturer
NMP code / Notes