Regular maintenance has 4 stages:
Daily inspection:
•
Visually inspect machine for any damaged parts, damaged cords
or electrical connections and
•
Check that the paper filter bag is neither full nor damaged.
Monthly maintenance:
•
Check the brush strips on the floor nozzle - if worn out these
should be changed.
•
Check the cartridge filter - should it be cleaned or replaced?
6 month maintenance:
•
Change the exhaust filter.
Annual check up:
•
Clean the cord and inspect for damaged insulation.
•
Clean and lubricate the wheels and castors.
•
Check all machine functions.
GB.9.2
Replacement of Filters
Note:
Please use only original Nobles filters and take
note of the instructions on the filter or filter pack!
Spare filters can be purchased from your Nobles distributor. Please
note that only genuine Nobles filters are guaranteed to give a constant
high filter performance.
WARNING
Hazardous Voltage. Shock or electrocution can
result. Unplug machine before servicing.
GB.9.2.1
Paper filter bag
•
Please take note of the information printed on each original paper
filter bag - it will assist you when changing the bag.
•
Firstly hold the coupling of the suction hose, rotate this anti-
clockwise and remove the coupling from the tank connector.
•
Hold onto the tab of the filter bag closing flange and gently pull
upwards. This will automatically close the flange (preventing any
dust from escaping) and the bag will slide upwards and out of the
tank
•
The new paper filter bag may now be installed. Simply locate the
cardboard edges of the paper bag mounting plate into the locating
grooves in the tank and slide the bag down into position.