![Nobles SPEED SCRUB 350 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/nobles/speed-scrub-350/speed-scrub-350_operators-manual_1698213030.webp)
30
Speed Scrub 350 9016424 (09-2017)
OPERATION
CIRCUIT BREAKER PANEL
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
The machine is equipped with resettable circuit
breakers to protect the machine from a current
overload. If a circuit breaker trips, disconnect the
battery cable connection and reset the breaker
by pressing the reset button after the breaker
has cooled down. Reconnect the battery cable
connection. If the circuit breaker does not reset or
continues to trip contact service personnel.
Open the access door to access the circuit breaker
panel.
Circuit
Breaker
Rating
Circuit Protected
CB1
4 A
Key switch
CB2
10 A
ec-H2O, automatic battery
watering
CB3
70 A
Propel controller
FOR SAFETY: When servicing machine,
all repairs must be performed by trained
personnel.
HOUR METER
The hour meter records the number of hours the
machine has been operated. Use the hour meter
to perform speci
fi
c maintenance procedures and to
record service history.