OPERATION
Speed Scrub
t
2601 Cylindrical Brush (12–02)
9
4.
With the double bristle row end towards you, guide
the brush into the drive hub (Figure 8).
NOTE: Installing the double bristle row end opposite of
drive hub will prevent brush streaking while scrubbing.
DOUBLE ROW
OF BRISTLES
FIG. 8
5.
Align idler plate on brush end and refasten
latches.
6
Repeat steps for other brush on opposite side of
scrub head.
7.
Check for proper brush pattern (see ADJUSTING
BRUSHES).
FILLING SOLUTION TANK
1.
Transport machine to filling station. Raise
squeegee and scrub head when transporting.
2.
Turn the main power switch to the OFF position.
3.
The solution tank is equipped with front and rear
filling ports for your convenience (Figure 9). Fill
solution tank with 64L (17 gal) of clean water,
60
°
C (140
°
F) maximum temperature. The clear
tube below the rear fill port indicates the amount of
water in solution tank.
FIG. 9
NOTE: When filling solution tank with a bucket, make
sure that bucket is clean. Do not use the same bucket
for filling and emptying the machine.
4.
Pour a recommended cleaning agent into solution
tank according to mixing instructions on bottle.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ATTENTION: Use only recommended cleaning
agents, DO NOT use substitutes. Consult an
authorized distributor for recommendations.
WARNING: Do Not Use Flammable Liquids Or
Operate Machine In Or Near Flammable Liquids,
Vapors Or Combustible Dusts.
ADJUSTING CONTROL GRIP HEIGHT
The machine has three control grip height settings.
To adjust, squeeze together the two levers below
console and lift or lower console to a comfortable
operating height (Figure 10).
FIG. 10