Use and Maintenance Manual model “A11V - C ZENITH & A11 V PLUS ZENITH”
28
ENGLISH
PHASE
DESCRIPTION
Management was chosen of the
ambient temperature
using an external thermostat (not
supplied by the manufacturer)
With the AIR CON. COMFORT en-
abled, the product automatically
switches off on reaching the am-
bient setting set (see relative para-
graph).
The appliance automatically man-
ages the power to the fireplace and
ventilation (where present and ena-
bled) to guarantee better comfort
(see specific paragraph).
The appliance works with
ventilation at the maximum speed
to speed up heating
of the environment.
(see relative paragraph)
The appliance optimises
combustion by reducing the pellet
load, however yield is guaranteed.
THERMOSTAT
AIR CON. COMFORT
AUTO
POWERFUL
OPTIMAL FLAME
15 SIGNALS CONCISE DIAGRAM
PHASE
DESCRIPTION
The appliance is in the alarm
status, consult the
“ALARMS” chapter to check the
type.
The appliance signals an
anomaly, without causing it to
switch off. See “ANOMALIES CON-
CISE DIAGRAM”.
The handheld device batteries are
almost flat.
The handheld device batteries
are flat. Replace
them.
The threshold for the working hours
set has been reached. You are ad-
vised to request extraordinary
maintenance of the appliance
by authorised staff.
ALARM
ANOMALY
BATTERY 10%
FLAT BATTERY
SERVICE HOURS
PHASE
DESCRIPTION
The appliance signals a malfunc-
tion of the sensor controlling correct
combustion. For safety purposes,
while waiting for the technician, the
appliance is set to saving mode.
The maximum smoke temperature
threshold has been reached; the
appliance for a period sets to saving
mode with ventilation at maximum
power to cool the body.
If the quantity of pellets is high for
the power of the machine. In P/E
mix, reduce the pellet load working
on the % (see specific
paragraph)
The appliance signals a malfunction
of the probe detecting the flame.
For safety purposes, while waiting
for technical intervention, the appli-
ance sets to saving mode.
S.PRESSURE FAULT
PHASE
DESCRIPTION
The anomaly is presented when
the user opens the door or ash pan
or pellet door; at this point, pellet
loading inside the brazier stops and
the electronics emit an acoustic sig-
nal. The user, to return to correct op-
eration, must
close the doors. If this
operation is not carried out, the
product signals an alarm.
Anomaly of the probe controlling
the temperature of the discharge
smoke, contact the authorised tech-
nician to solve the fault.
The anomalies, differing from alarms, are signals
which automatically reset, once the cause that
generated them has been eliminated.
Furthermore, the signalling does not cause the ap-
pliance to switch off, guaranteeing however
heating.
16 ANOMALIES CONCISE DIAGRAM
HOT SMOKE
EXCESS LOAD
S.FLAME FAULT
Some anomalies, to be resolved, need technical in-
tervention by authorised
staff. Despite the appliance continuing to work, the
user must ensure the
problem is resolved.
Negligence causes the product
to malfunction
.
Содержание A11 C ZENITH
Страница 1: ...EN Installation use and maintenance manual A11 V ZENITH A11 C ZENITH A11 V PLUS ZENITH...
Страница 35: ......