background image

Use and Maintenance Manual model “A11V - C ZENITH & A11 V PLUS ZENITH”

28 

ENGLISH

PHASE

DESCRIPTION

Management was chosen of the 

ambient temperature 

using an external thermostat (not 

supplied by the manufacturer)

With the AIR CON. COMFORT en-

abled, the product automatically 

switches off on reaching the am-

bient setting set (see relative para-

graph).

The appliance automatically man-

ages the power to the fireplace and 

ventilation (where present and ena-

bled) to guarantee better comfort 

(see specific paragraph).

The appliance works with  

ventilation at the maximum speed 

to speed up heating 

of the environment.

(see relative paragraph)

The appliance optimises 

combustion by reducing the pellet 

load, however yield is guaranteed. 

THERMOSTAT

AIR CON. COMFORT

AUTO

POWERFUL

OPTIMAL FLAME

15 SIGNALS CONCISE DIAGRAM

PHASE

DESCRIPTION

The appliance is in the alarm 

status, consult the 

“ALARMS” chapter to check the 

type.

The appliance signals an 

anomaly, without causing it to 

switch off. See “ANOMALIES CON-

CISE DIAGRAM”.

The handheld device batteries are 

almost flat. 

The handheld device batteries 

are flat. Replace 

them.

The threshold for the working hours 

set has been reached. You are ad-

vised to request extraordinary 

maintenance of the appliance 

by authorised staff.

ALARM

ANOMALY

BATTERY 10%

FLAT BATTERY

SERVICE HOURS

PHASE 

DESCRIPTION

The appliance signals a malfunc-

tion of the sensor controlling correct 

combustion. For safety purposes, 

while waiting for the technician, the 

appliance is set to saving mode. 

The maximum smoke temperature 

threshold has been reached; the 

appliance for a period sets to saving 

mode with ventilation at maximum 

power to cool the body.

If the quantity of pellets is high for 

the power of the machine. In P/E 

mix, reduce the pellet load working 

on the % (see specific 

paragraph)

The appliance signals a malfunction 

of  the  probe  detecting  the  flame. 

For safety purposes, while waiting 

for technical intervention, the appli-

ance sets to saving mode. 

S.PRESSURE FAULT

PHASE

DESCRIPTION

The anomaly is presented when 

the user opens the door or ash pan 

or pellet door; at this point, pellet 

loading inside the brazier stops and 

the electronics emit an acoustic sig-

nal. The user, to return to correct op-

eration, must 

close the doors. If this 

operation is not carried out, the 

product signals an alarm.

Anomaly of the probe controlling 

the temperature of the discharge 

smoke, contact the authorised tech-

nician to solve the fault.

The anomalies, differing from alarms, are signals 

which automatically reset, once the cause that 

generated them has been eliminated.

Furthermore, the signalling does not cause the ap-

pliance to switch off, guaranteeing however 

heating.

16 ANOMALIES CONCISE DIAGRAM

HOT SMOKE

EXCESS LOAD

S.FLAME FAULT

Some anomalies, to be resolved, need technical in-

tervention by authorised 

staff. Despite the appliance continuing to work, the 

user must ensure the 

problem is resolved. 

Negligence causes the product 

to malfunction

.

Содержание A11 C ZENITH

Страница 1: ...EN Installation use and maintenance manual A11 V ZENITH A11 C ZENITH A11 V PLUS ZENITH...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...ld device keys 14 7 3 Description of handheld device display 14 7 4 Flat battery signalling 15 7 5 Concise icons diagram 15 8 Menu browsing 16 9 First start up instructions 16 9 1 Date and time settin...

Страница 4: ...ing activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the...

Страница 5: ...tenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user...

Страница 6: ...nment making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negat...

Страница 7: ...other rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary...

Страница 8: ...ation In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the i...

Страница 9: ...flammable parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in parti...

Страница 10: ...act with hot parts and must remain accessible after installation To carry out electrical connection proceed as de scribed below connect the power supply cable on the back of the appliance connect the...

Страница 11: ...nt product operation is not guaranteed In this phase the authorised technician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broken pellet r...

Страница 12: ...utilizzato per la costruzione dell oggetto rappresentato n venire comunicato a terzi o riprodotto La Societ proprietaria tutela i propri diritti a rigore di legge All proprietary rights reserved by N...

Страница 13: ...el is loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to...

Страница 14: ...wing chapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as report...

Страница 15: ...the appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of t...

Страница 16: ...Scroll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar...

Страница 17: ...inhibits manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9...

Страница 18: ...eplace as soon as the temperature in the premises goes under the required setting optimisation of combustion and acoustic comfort During first start up of the product unpleasant odours may occur or sm...

Страница 19: ...AND BY screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set...

Страница 20: ...Thermostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to fol...

Страница 21: ...e the switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte na...

Страница 22: ...ELLET and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you wa...

Страница 23: ...at is installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing t...

Страница 24: ...se simply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct cha...

Страница 25: ...ne to channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external...

Страница 26: ...ture setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the L...

Страница 27: ...TART PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlight...

Страница 28: ...or controlling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a...

Страница 29: ...Service ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the proble...

Страница 30: ...blem persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank...

Страница 31: ...urfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damage to the surface of the product 18 1 CLEANING THE FIREPLACE Open the fire doo...

Страница 32: ...t and which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations mu...

Страница 33: ...ct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chambe...

Страница 34: ...AL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION tech...

Страница 35: ......

Страница 36: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0011N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: