Use and Maintenance Manual model “A11V - C ZENITH & A11 V PLUS ZENITH”

ENGLISH

1

INTRODUCTION

The product 

by Nobis 

 was designed and manufactured 

in compliance with the reference standards for the 

manufacturing products (EN13240 wood stoves, 

EN14785 pellet appliances, EN13229 fireplaces/

inserts for wood, EN12815 wood stoves), with 

high quality materials. The products also comply 

with the essential requirements of the Directive 2006/95/

EC

(Low Voltage) and the Directive 2004/108/EC 

(Electromagnetic Compatibility).

The printing, translation and reproduction, 

even partial, of this manual is intended 

as binding by the manufacturer's authorisation and

the content of working logic and explanatory 

figures is considered not be be disclosed.

Always consult the authorised technicians if in 

doubt and/or confused by operation of the 

the product.

The manufacturer reserves the right to make changes to 

specifications and technical and/or working features of 

the product at any time without prior warning.

1.1 SYMBOLS

The following manual contains symbols which high-

light the importance of particular descriptions or con-

cepts;

INFORMATION: Compliance with the specifications 

guarantees correct operation of the product.

ATTENTION: Symbol used to identify 

particularly important information

DANGER: The presence of this symbol 

indicates utmost attention is required, to guarantee 

user and product safety.

1.2 PLANNED USE

The product in this manual, is a 

fireplace for domestic heating, 

feed by automatic loading and exclusively with wood 

pellets.

The product was designed and manufactured to work in 

safety if the following conditions occur:

• installation by specialist staff 

   according to the specific reference standards;

• use within the limits declared on the product 

   data sheet and in this manual;

• compliance with technical procedures described in the 

   manual;

• carrying out routine maintenance within the times   

   and methods indicated in this manual;

• prompt execution of extraordinary 

   maintenance if necessary 

   (malfunctioning);

• activity and maintenance of safety devices 

   (do not remove or bypass this devices).

1.3 IMPROPER USE

The product must be intended for the use for which it 

was expressly designed; for any other use, the manu-

facturer cannot 

be held in any way liable for damage caused to 

people, animals or property. 

Improper use is intended as:

• use of the product as an incinerator;

• use of the product with fuel other than   

   wood pellets with a diameter of 6 mm;

• use of the product with liquid fuel;

• use of the product with the fire door open and/or 

   glass broken and/or ash pan removed and/or 

   pellet tank open.

Any other use of the appliance other than that 

planned must be authorised in advance 

in writing by the manufacturer.

Furthermore, the manufacturer cannot be held in 

any way liable for errors in installation, adjustment or 

maintenance of 

the product.

1.4 IMPORTANCE OF THE MANUAL

The manual has the purpose of providing essential 

rules for correct installation, use and maintenance of 

the product.

PRESERVATION: Keep the manual in a place that is 

easy and quick to find;

DETERIORATION  OR  LOSS:  Consult  the  official  site  to 

download the manual;

PRODUCT TRANSFER: In the event of sale between pri-

vate individuals of the product, the owner is obliged 

to 

deliver the product with the following manual.  

1.5 GENERAL SAFETY WARNINGS

Non-compliance with the provisions of this manual can 

cause damage to people, animals and property.

• Installation, testing of the system, functionality     

   testing and initial calibration of the 

   product must only be carried out by  

   qualified and authorised staff.

• The product must be connected to a single chimney 

   flue that guarantees the draught declared by the     

   manufacturer and which complies with the installa-

tion 

   standards outlined in the assembly location of the  

   product.

• The premises where the product is installed must be 

   adequately ventilated (air intake).

• Do not touch the hot surfaces without adequate   

   protective equipment, to avoid burns.

• When in operation, the external surfaces 

   reach high temperatures.

• It is forbidden to make changes to the product unless   

   expressly communicated in writing by the 

   manufacturer.

• In the event of fire in the chimney flue, contact   

   the Fire Brigade immediately.

Содержание A11 C ZENITH

Страница 1: ...EN Installation use and maintenance manual A11 V ZENITH A11 C ZENITH A11 V PLUS ZENITH...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...ld device keys 14 7 3 Description of handheld device display 14 7 4 Flat battery signalling 15 7 5 Concise icons diagram 15 8 Menu browsing 16 9 First start up instructions 16 9 1 Date and time settin...

Страница 4: ...ing activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the...

Страница 5: ...tenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user...

Страница 6: ...nment making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negat...

Страница 7: ...other rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary...

Страница 8: ...ation In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the i...

Страница 9: ...flammable parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in parti...

Страница 10: ...act with hot parts and must remain accessible after installation To carry out electrical connection proceed as de scribed below connect the power supply cable on the back of the appliance connect the...

Страница 11: ...nt product operation is not guaranteed In this phase the authorised technician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broken pellet r...

Страница 12: ...utilizzato per la costruzione dell oggetto rappresentato n venire comunicato a terzi o riprodotto La Societ proprietaria tutela i propri diritti a rigore di legge All proprietary rights reserved by N...

Страница 13: ...el is loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to...

Страница 14: ...wing chapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as report...

Страница 15: ...the appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of t...

Страница 16: ...Scroll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar...

Страница 17: ...inhibits manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9...

Страница 18: ...eplace as soon as the temperature in the premises goes under the required setting optimisation of combustion and acoustic comfort During first start up of the product unpleasant odours may occur or sm...

Страница 19: ...AND BY screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set...

Страница 20: ...Thermostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to fol...

Страница 21: ...e the switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte na...

Страница 22: ...ELLET and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you wa...

Страница 23: ...at is installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing t...

Страница 24: ...se simply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct cha...

Страница 25: ...ne to channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external...

Страница 26: ...ture setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the L...

Страница 27: ...TART PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlight...

Страница 28: ...or controlling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a...

Страница 29: ...Service ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the proble...

Страница 30: ...blem persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank...

Страница 31: ...urfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damage to the surface of the product 18 1 CLEANING THE FIREPLACE Open the fire doo...

Страница 32: ...t and which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations mu...

Страница 33: ...ct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chambe...

Страница 34: ...AL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION tech...

Страница 35: ......

Страница 36: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0011N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: