Use and Maintenance Manual model “A11V - C ZENITH & A11 V PLUS ZENITH”

27 

ENGLISH

ENGLISH

13 PHASES CONCISE DIAGRAM

PHASE

DESCRIPTION

- The phase starts to pre-heat the re 

  sistor and the pellet starts to  

  fall in the brazier.

- The pellet switches on by taking ad

  vantage of the heat in the inlet air 

  which  passes by the duct of the 

  incandescent resistor.

- Pellet loading  restarts and the    

  flame develops.

The appliance has terminated the 

switch on phase and  

goes to the working power set.

The desired ambient temperature is 

reached.

The cleaning phase is enabled of 

the brazier without movement of the 

cleaner (periodic function).

The  brazier  cleaning  phase  is  run

-

ning with the cleaner enabled. The 

appliance switches off and switches 

back on autonomously.

Switch on is required after a cooling 

phase. 

Having reached this condition, 

the appliance automatically starts.

The appliance is in the switch off 

phase and the cooling 

phase has not yet 

terminated.

The appliance is OFF and all the 

motors are disabled.

SWITCH ON

WORK

SAVING

BRAZIER CLEANING

CLEANER ENABLED

FINAL CLEANING

OFF

WAITING FLAME

FLAME PHASE

RESTART

PHASE

DESCRIPTION

Ambient setting in MAN 

therefore the appliance only works 

with the power to the fireplace 

set (never going to 

saving) 

MAN WORK

14 FUNCTIONS CONCISE DIAGRAM

Edit the data highlighted using the keys

Confirm the data changed using the key

Repeat the same operation to set the following pa-

rameter;

OK

12.6 DISPLAY CHANNELLING STATUS

To display the channelling status, from the STAND-BY 

status, press the key       .

The display screen follows:

SET RH 

CHANNELLED  

AMBIENT

TEMP. RH CHAN-

NELLED AMBIENT

SPEED 

RH VENTILATION

When the POWERFUL function is enabled, in display 

status, you can also see that channelling is in this 

mode, as in the figure below.

Having confirmed setting of the 

RH channelling, confirm with the key         and re

-

peat the same sequence of operations for the 

LH channelling.           

OK

Edit the data highlighted using the keys

Confirm the data changed using the key

Repeat the same operation to set the following pa-

rameter;
To return to the STAND-BY screen, use the 

key       , confirming all the settings.

OK

OK

SET LH 

CHANNELLED 

AMBIENT

TEMP. LH CHAN-

NELLED AMBIENT

SPEED 

LH VENTILATION

Setting the ambient temperature for 

channelling, this is only managed if the TEMPERA-

TURE CONTROL function is enabled, previously seen, 

ENABLE T.EXT in SET SETTING disabled in the CHAN-

NELLING menu. 

Содержание A11 C ZENITH

Страница 1: ...EN Installation use and maintenance manual A11 V ZENITH A11 C ZENITH A11 V PLUS ZENITH...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...ld device keys 14 7 3 Description of handheld device display 14 7 4 Flat battery signalling 15 7 5 Concise icons diagram 15 8 Menu browsing 16 9 First start up instructions 16 9 1 Date and time settin...

Страница 4: ...ing activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the...

Страница 5: ...tenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user...

Страница 6: ...nment making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negat...

Страница 7: ...other rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary...

Страница 8: ...ation In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the i...

Страница 9: ...flammable parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in parti...

Страница 10: ...act with hot parts and must remain accessible after installation To carry out electrical connection proceed as de scribed below connect the power supply cable on the back of the appliance connect the...

Страница 11: ...nt product operation is not guaranteed In this phase the authorised technician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broken pellet r...

Страница 12: ...utilizzato per la costruzione dell oggetto rappresentato n venire comunicato a terzi o riprodotto La Societ proprietaria tutela i propri diritti a rigore di legge All proprietary rights reserved by N...

Страница 13: ...el is loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to...

Страница 14: ...wing chapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as report...

Страница 15: ...the appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of t...

Страница 16: ...Scroll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar...

Страница 17: ...inhibits manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9...

Страница 18: ...eplace as soon as the temperature in the premises goes under the required setting optimisation of combustion and acoustic comfort During first start up of the product unpleasant odours may occur or sm...

Страница 19: ...AND BY screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set...

Страница 20: ...Thermostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to fol...

Страница 21: ...e the switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte na...

Страница 22: ...ELLET and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you wa...

Страница 23: ...at is installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing t...

Страница 24: ...se simply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct cha...

Страница 25: ...ne to channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external...

Страница 26: ...ture setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the L...

Страница 27: ...TART PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlight...

Страница 28: ...or controlling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a...

Страница 29: ...Service ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the proble...

Страница 30: ...blem persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank...

Страница 31: ...urfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damage to the surface of the product 18 1 CLEANING THE FIREPLACE Open the fire doo...

Страница 32: ...t and which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations mu...

Страница 33: ...ct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chambe...

Страница 34: ...AL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION tech...

Страница 35: ......

Страница 36: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0011N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: